Return to search

Avaliação histomorfométrica da densidade dos osteócitos ao redor de 99 implantes em forma de platôs removidos de humanos em função até 18 anos

Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2017. / Made available in DSpace on 2017-05-31T14:18:17Z (GMT). No. of bitstreams: 1
345989.pdf: 5016386 bytes, checksum: 6dc8fdf1f963cd3c9f58b948adab349f (MD5)
Previous issue date: 2017 / Proposição: O objetivo deste trabalho foi avaliar a densidade dos osteócitos (DO) ao redor de implantes removidos de humanos, e associá-la ao tempo de carga funcional e a variáveis relacionadas aos pacientes e aos implantes. Materiais e Métodos: Ao longo de 17 anos, 221 implantes em forma de platôs (Bicon LLC, Boston, MA, USA) removidos de humanos por razões protéticas foram obtidos. Este estudo avaliou somente implantes unitários, funcionais por no mínimo 4 meses, e com dados relativos aos pacientes - arco (maxila e mandíbula) e região (anterior e posterior) - e aos implantes (superfície, diâmetro e comprimento) presentes. Assim, um total de 99 implantes com dados suficientes foram incluídos e preparados histologicamente de maneira não descalcificada. Análise histomorfométrica da DO foi realizada e relacionada ao tempo de carga funcional e às variáveis independentes referentes aos pacientes e aos implantes. Resultados: Nenhuma característica dos implantes ou pacientes pode ser estatisticamente relacionada à DO; houve uma discreta diminuição na DO ao longo do tempo. Conclusões: Sugere-se que as características únicas dos implantes em forma de platôs foram capazes de suprimir a influência de variáveis relativas aos implantes e pacientes sobre a DO, somado à sua discreta diminuição em função do tempo de carga funcional, demonstrando que um padrão ósseo homogêneo se desenvolve ao redor destes dispositivos.<br> / Abstract : Purpose: The aim of this study was to assess the effect of functional loading time and other clinical/implant design variables on osteocyte density (OD) human retrieved dental implants. Materials and Methods: Due to prosthetic reasons, 221 human plateau root form implant retrievals from the same manufacturer (Bicon LLC, Boston, MA, USA) were obtained over a period of approximately 17 years. This study analyzed single implants that were on functional loading for at least 4 months, presenting data regarding patients - arch (maxilla and mandible) and region (anterior and posterior) - and implants (surface, diameter and length). Then, 99 implants with sufficient data were included and histologically prepared in a non-decalcified protocol. DO histomorphometric analysis was performed and assessed as a function of time of functional loading and multiple patients and implants independent variables. Results: No implant and patient related characteristics were statistically related to OD; there was a slightly decrease in OD overtime. Conclusions: Results suggest that the unique characteristics of plateau root form implants were able to suppress any influence of patient and implant parameters on OD and along with its slight decrease overtime, showing that a homogeneous bone pattern develops around these devices.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/176063
Date January 2017
CreatorsGil, Luiz Fernando
ContributorsUniversidade Federal de Santa Catarina, Gil, José Nazareno, Coelho, Paulo Guilherme
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format86 p.| il., gráfs., tabs.
Sourcereponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds