Return to search

Resistência de união de pinos de fibra cimentados com diferentes materiais e técnicas de ativação à dentina radicular

Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2011 / Made available in DSpace on 2012-10-25T16:53:08Z (GMT). No. of bitstreams: 1
293138.pdf: 1305828 bytes, checksum: e3c716c2f062ec338fa8535bf2510007 (MD5) / O sucesso clínico de um tratamento restaurador indireto depende de alguns fatores, dentre eles o tipo de cimento e a técnica de cimentação utilizada, que são responsáveis pela interação entre a restauração e o dente. Objetivou-se com este estudo avaliar, in vitro, a influência dos métodos de ativação (química, fotoativação convencional e pulso tardio) de um cimento resinoso auto adesivo e com condicionamento ácido total, sobre a resistência de união, sob push- out, de pinos de fibra fixados na dentina radicular. As coroas de sessenta pré-molares humanos hígidos foram cortados 1mm acima da junção cemento-esmalte, sendo o remanescente radicular padronizado em 16mm ± 1mm. Os dentes foram tratados endodonticamente e após uma semana os condutos preparados com brocas específicas para cimentação dos pinos. Os espécimes foram distribuídos aleatoriamente em 6 grupos (n=10), de acordo com o cimento utilizado e o método de ativação: G1 (RelyX ARC - fotoativação convencional), G2 (RelyX ARC - Ativação química), G3 ( RelyX ARC - fotoativação por pulso tardio), G4 (RelyX U 100 - fotoativação convencional), G5 (RelyX U100 - Ativação química) e G6 (RelyX U 100 - fotoativação por pulso tardio). Após uma semana de cimentação dos pinos, os espécimes foram seccionados em 6 fatias de 1 mm, sendo 2 fatias referentes a cada terço (cervical, médio e apical). Posteriormente, realizou-se o teste de cisalhamento por extrusão (push-out) em uma velocidade de 0,5mm/min. Os dados foram submetidos à análise de variância (ANOVA 2) e teste de Tukey. O cimento RelyX U 100 (Grupos 4, 5 e 6) apresentou, numericamente, maior resistência de união que o cimento RelyX ARC, em todas as técnicas de ativação, embora não tenha sido observada significância estatística na ativação química e na fotoativação por pulso tardio (p>0,05). No cimento RelyX ARC a ativação química apresentou menor valor de resistência de união que a ativação por pulso tardio. No cimento RelyX U 100 a ativação química apresentou menor valor de resistência de união que a fotoativação convencional. A técnica de fotoativação por pulso tardio não promoveu maiores valores de resistência de união em comparação a fotoativação convencional, dentro do mesmo grupo de cimento. Não houve diferenças estatísticas nos valores de resistência de união entre os terços radiculares, dentro de cada grupo. / The clinical success of an indirect restorative treatment depends of some factors as the kind of material used as cement and the technique of cementation used. These factors are responsible by the interaction restoration and teeth. The aim of this study was to evaluate, in vitro, the influence of activation methods (chemical, conventional photoactivation and pulse delay) of a self adhesive and a total etch resin cement over the bond strength of fiber posts to root dentin, with push-out test. The clinical crowns of sixty higid human pre-molars were removed up to approximately 1.0 mm above the cement enamel junction, where the root length was standardized in 16mm ± 1mm. The teeth were endodontically treated and after one week the post spaces were prepared with a tapered drill specific for the post system. The specimens were divided randomly in 6 groups (n=10), according to the resin cement and activation methods used: G1 (RelyX ARC # Conventional photoactivation), G2 (RelyX ARC # Chemical), G3 (RelyX ARC # Pulse-delay), G4 (RelyX U 100 - Conventional photoactivation), G5 (RelyX U100 - Chemical) e G 6 (RelyX U 100 # Pulse-delay). One week after the posts cementation, the specimens were sectioned in 6 slices of 1 mm, where 2 slices are referring to each third (cervical, medium and apical). After that, it was done the extrusion shear a test (push-out) with speed of 0,5mm/min. The data were analyzed statistically using ANOVA 2 and Tukey test. The RelyX U 100 cement showed, numerically, higher bond strength than RelyX ARC cement in all activation methods, but statistical significance was observed only with the conventional photoactivation (p<0,05). With RelyX ARC cement, chemical activation showed lesser bond strength value than pulse delay photoactivation. With RelyX U 100 cement, chemical activation showed lesser bond strength value than conventional photoactivation. The pulse-delay activation didn't promote greater bond strength values when compared to conventional photoactivation to the same cement group. There were no statistical differences on bond strength values between the root thirds inside each group.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufsc.br:123456789/94842
Date25 October 2012
CreatorsMattei, Fabiana Paladini
ContributorsUniversidade Federal de Santa Catarina, Prates, Luiz Henrique Maykot, Chain, Marcelo Carvalho
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format80 p.| il., grafs., tabs.
Sourcereponame:Repositório Institucional da UFSC, instname:Universidade Federal de Santa Catarina, instacron:UFSC
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds