Return to search

Estudo da ocorrência de tetraciclinas e estrógenos em água superficial, subterrânea e esgoto tratado na cidade de Campo Grande (MS)

Made available in DSpace on 2014-06-11T19:35:06Z (GMT). No. of bitstreams: 0
Previous issue date: 2008-09-19Bitstream added on 2014-06-13T20:45:59Z : No. of bitstreams: 1
souza_jbg_dr_araiq.pdf: 923971 bytes, checksum: 6085d4ee0078ecc2d198c1ff65ff5cdd (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os antibióticos, oxitetraciclina, tetraciclina, clorotetraciclina e doxiciclina, os estrógenos naturais, estrona, 17 β-estradiol, e o sintético 17 α-etiniletradiol tornaram-se objetos de estudo nos últimos anos devido aos impactos ambientais que podem causar, mesmo estando presentes em ambientes aquáticos em baixas concentrações provocando alterações biológicas através de diversos mecanismos de ação. Por este motivo, este trabalho teve como objetivo validar métodos para análise dessas substâncias em água superficial, água subterrânea e esgoto sanitário tratado. O método validado para análise de antibióticos baseou-se em cromatografia líquida com detector ultravioleta, foi utilizada extração em fase sólida com cartuchos Oásis-HLB, obtendo-se limites de quantificação de 6,5 ng L-1 para a oxitetraciclina e tetraciclina e 15 ng L-1 para clorotetraciclina e doxiciclina, em água superficial e água subterrânea, não foi possível a validação do método para esgoto sanitário tratado. A cromatografia líquida com detecção por fluorescência foi utilizada para a determinação dos estrógenos. A otimização do preparo das amostras foi obtida utilizando extração em fase sólida com cartuchos C18, o limite de quantificação para a estrona foi de 0,6 μg L-1 e de 6,25 ng L-1 para o 17 β-estradiol e 17 α-etinilestradiol, para as matrizes de água superficial, subterrânea e esgotos sanitário tratado. Os resultados referentes à validação do método mostraram níveis aceitáveis para a recuperação (entre 76 e 118%) e coeficiente de variação (entre 1 e 13%), o que atesta a exatidão e a precisão do mesmo para os níveis de concentração estudados, para todas as matrizes. No estudo em Campo Grande, as amostras de água superficial foram coletadas nos rios Lageado e Guariroba próximo aos pontos de captação do sistema de abastecimento público... / The antibiotics, oxytetracycline, tetracycline, chlortetracycline and doxycycline and the strogenes: naturals, estrone, 17β-estradiol, and the sinthetic 17 α-ethinylestradiol becaome object of study in the last years due to environmental impacts and serious health problems that they can cause, even when they are present in aquatic environment at low concentrations provoking biological changes though the several mechanisms of action. For this reason, this work had as goal certificate methods to analyze these chemicals in superficial water, subterranean water and treated sanitary drainage. The certificate method to antibiotic analyzes was based in liquid chromatography with ultraviolet detector, it was used extraction in solid phase with cartridge Oasis-HLB, obtaining with that limits to quantification of 6,5ng L-1 to the oxytetracycline and tetracycline and 15 ng L-1 and 6,25 ng L-1 to the 17 β-estradiol and 17 α-etinilestradiol, it was not possible the method validation for treated sanitary drainage. The liquid chromatographic with fluorescence detection was used to estrogens determination. The optimization os samples prepare was obtained using ecxtraction in solid phase with C18 cartridge, the limit of quantification to the estrone was 0,6 μg L-1 and 6,25 ng L-1 to the 17 β-estradiol and 17 α- ethinylestradiol, to the matrixes of subterranean water and treat sanitary drainage. In Campo Grande resource, the samples of capitation of superficial water were collected at the rivers Lageado and Guariroba next to the capitation places of public supplying system. Subterranean water samples and treated sanitary drainage were obtained at the campus of Universidade Federal de Mato Grosso do Sul. The results referring to the validation of the method shown acceptable levels to the recover (between 76 to 118%) and the variation coefficient (between 1 to 13%), these show... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/105696
Date19 September 2008
CreatorsSouza, João Batista Gomes de [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Marchi, Mary Rosa Rodrigues de [UNESP], Poppi, Nilva Ré [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format140 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0048 seconds