Back to search

University of Alberta

3D-3D rigid registration of echocardiographic images obtained from apical window

Abstract

dc:description.abstract

Echocardiography is widely used in clinics to assess heart function and structure. However, it suffers from a limited field of view. There are no algorithms that enable perfect alignment of 3D echocardiographic images captured from various angles to improve image quality and broaden the field of view. This study proposes an accelerated sequential Monte Carlo (SMC) algorithm for 3D-3D rigid registration of transthoracic echocardiographic images with significant and limited overlap taken from the apical window that is robust to the noise and intensity variation in ultrasound images. The SMC algorithm estimates the translational and rotational components of the rigid transform through an iterative process and requires an initial approximation of the translation and rotation limits. We perform registration in two ways: image-based registration computes the transform to align the end-diastolic frame of the apical nonstandard image to the apical standard image and applies the same transform to all frames of the cardiac cycle, whereas mask-based registration approach uses the binary masks of the left ventricle in the same way. The SMC and exhaustive search (EX) algorithms were evaluated for 4D temporal sequences recorded from 7 volunteers who participated in a study conducted at the Mazankowski Alberta Heart Institute. The evaluations demonstrate that the mask-based approach of the accelerated SMC yielded a Dice score value of 0.819 ± 0.045 for the left ventricle and gained 16.7 × speedup compared to the CPU version of the SMC algorithm. The mask-based accelerated SMC-based approach performs well compared to the other approaches in terms of accuracy and computational time.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Grantor
University of Alberta
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Uruththirakodeeswaran, Thanuja
Advisors dc:contributor.advisor
  • Punithakumar, Kumaradevan (Radiology and Diagnostic Imaging)
  • Le, Lawrence (Radiology and Diagnostic Imaging)

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
Language dc:language.iso
en

Identifiers

dc:identifier.*
DOI dc:identifier.doi
https://doi.org/10.7939/83357

Chain of custody

source
Harvested from
University of Alberta
Base URL
era.library.ualberta.ca/oai
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Uruththirakodeeswaran, Thanuja. 3D-3D rigid registration of echocardiographic images obtained from apical window. Doctoral thesis, University of Alberta, 2025. https://doi.org/10.7939/83357