University of Alberta
A High-Performance Design to Overcome Critical Challenges of CMUTs While Enhancing Sensitivity and Acoustic Pressure
Abstract
dc:description.abstractCapacitive Micromachined Ultrasonic Transducers (CMUTs) are increasingly recognized as promising alternatives to traditional piezoelectric transducers in ultrasound imaging and sensing applications. Despite their potential, CMUTs face several key performance and reliability challenges, including high required actuation voltage, limited membrane deflection, dielectric charging, parasitic capacitance, and hysteresis in pull-in deflection. Recently, [ Dew et al., Nature Microsyst Nanoeng 8, 59 (2022)] from the Zemp lab group presented a high-performance rectangular CMUT that achieved almost three times the transmit pressure of piezoelectric transducer and mitigated the dielectric charging and hysteresis. This thesis presents a novel high-performance CMUT design aimed at addressing above limitations and further improving on the work of Dew et al. A step-structured CMUT architecture featuring long rectangular membranes is proposed to enhance membrane deflection and acoustic output at reduced DC bias voltages. Simulation results demonstrate that the proposed design achieves the same pull-in deflection as a conventional flat structure while requiring 28.7% less voltage. AC simulations further reveal a 10% increase in acoustic pressure. To improve sensitivity a fabrication process is proposed which should remove major sources of parasitic capacitance using silicon-on-sapphire (SOS) wafers and SiO2–SiO2 fusion bonding. These changes eliminate unwanted capacitive paths around the bonding pad and through the bulk substrate, effectively reducing dielectric charging and enhancing breakdown voltage by up to fivefold. Additional innovations include biasing electrode posts to the same potential as the membrane, which suppresses hysteresis near the pull-in point and minimizes dielectric field-induced charging after membrane collapse. Simulated capacitance-pressure behavior shows that the combined effects of structural design and parasitic capacitance elimination result in a 131% improvement in sensitivity compared to conventional flat CMUT structures, with the step structure contributing the most significantly to this enhancement. The proposed fabrication process uses low-stress oxidation, KOH wet etching for step formation, and precision wafer bonding to realize the proposed structure with high uniformity. Overall, this work provides a comprehensive solution to several persistent challenges in CMUT development, achieving lower voltage operation, improved sensitivity, reduced noise, and enhanced reliability. These advancements establish a strong foundation for the integration of CMUTs into next-generation medical imaging and high-performance sensing platforms.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Biomedical Engineering
- Grantor
- University of Alberta
- Year dc:date.issued
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Valizadeh Yaghmourali, Yousef
- Advisor dc:contributor.advisor
-
- Roger Zemp, Department of Electrical and Computer Engineering, Biomedical Engineering
Subjects
dc:subject × 10Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/83553