University of Alberta
Real-Time MLC Control and Latency Characterization on a Linac-MR
Abstract
dc:description.abstractReal-time tumor-tracked radiotherapy using multi-leaf collimator (MLC) tracking has the potential to significantly improve treatment conformality for mobile tumors affected by respiratory, cardiac, and other physiological motions. This approach enables reduced treatment margins and improved therapeutic ratios. Magnetic resonance imaging (MRI) guided implementations on linac-MR (LMR) systems are particularly promising due to superior soft-tissue contrast and the absence of imaging dose. However, inherent system latencies in MRI-based tracking arising from image acquisition, image processing, and mechanical MLC response must be accurately characterized to enable effective motion prediction and precise alignment between the beam and target. While real-time MLC control has been demonstrated on other LMR platforms, it had not been implemented or characterized on the Alberta LMR system. Furthermore, the effects of clinical parameters on MLC performance have not been systematically investigated. This thesis presents the first demonstration of real-time MLC control and mechanical latency characterization for non-invasive intrafractional tumor-tracked radiotherapy (nifteRT) on the Alberta LMR. A custom-designed proportional-integral-derivative (PID) controller was developed and optimized to minimize latency, and a novel camera-based external verification method was implemented to independently validate internal measurements. Mechanical latency was characterized across ten motion patterns, including synthetic waveforms and patient-derived tumor trajectories from lung, liver, and pancreas sites, under different gantry angles (0°, 90°, 180°, 270°), and using various maximum leaf velocities (5-50 mm/s) at the MLC. Measured latencies of 73.2-80.1 ms are well below the recommended 500 ms threshold for real-time tumor tracking systems by the American Association of Physicists in Medicine (AAPM) Task Group (TG) 76 report. Gantry angle was found to have no significant impact on latency, while a maximum leaf velocity threshold of ≥10 mm/s was identified as necessary for optimal MLC performance on this system. This work establishes the technical foundation for future integration of MLC control with the full nifteRT workflow, including accelerated MRI acquisition, auto-contouring, and motion prediction components, advancing the Alberta LMR system toward complete real-time adaptive radiation therapy for mobile tumors.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Master's
- Discipline thesis:degree_discipline
- Medical Physics
- Grantor
- University of Alberta
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Schultz, Benjamin D
- Advisor dc:contributor.advisor
-
- Yun, Jihyun (Oncology)
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- This thesis is made available by the University of Alberta Library with permission of the copyright owner solely for non-commercial purposes. This thesis, or any portion thereof, may not otherwise be copied or reproduced without the written consent of the copyright owner, except to the extent permitted by Canadian copyright law.
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- DOI dc:identifier.doi
- https://doi.org/10.7939/84461