Back to search

University of Arkansas

Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System

Abstract

dc:description.abstract

Septic arthritis is a severe joint infection that can rapidly destroy cartilage and cause lifelong disability if not diagnosed and treated promptly. Faster, bedside diagnostic tools are needed to reduce delays and support timely treatment decisions while preserving standard laboratory workflows. A syringe-mounted diffuse reflectance spectroscopy (DRS) system was developed for rapid, sterile, point-of-care measurement of synovial fluid optical properties. Broadband light (400–650 nm) was delivered and collected through the syringe barrel without contaminating the sample. An empirical lookup table (LUT) and a boundary-aware Monte Carlo (MC) model were implemented to extract absorption (μₐ) and reduced scattering (μs′) coefficients from the measured spectra. Optical phantom studies confirmed that the system retrieves optical properties within 5–15% of known reference values and achieves signal-to-noise ratios exceeding 50 dB. Prospective patient samples (n = 19) demonstrated that scattering amplitude and reflectance band ratios (e.g., R₄₉₀/R₆₀₀) distinguish infected from non-infected fluid with ≥85% sensitivity and ≥90% specificity in under five minutes. The non-contact design preserves fluid sterility for culture confirmation. This work demonstrates a practical path from proof-of-concept to deployable point-of-care optical screening for septic arthritis, supporting faster treatment decisions and improved patient outcomes.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy in Engineering (PhD)
Level thesis:degree_level
Dissertation
Department thesis:degree_department
Biomedical Engineering
Year dc:date.available
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Drewke, Erin Elizabeth
Advisor dc:contributor.advisor
  • Rajaram, Narasimhan
Contributors dc:contributor
  • Jensen, Hanna
  • Wolchok, Jeffery

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
Repository record dc:identifier
https://scholarworks.uark.edu/etd/5931

Chain of custody

source
Harvested from
University of Arkansas
Base URL
scholarworks.uark.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Drewke, Erin Elizabeth. Advancing Point-of-Care Diagnosis of Joint Infection Using a Diffuse Reflectance Spectroscopy (DRS) System. Dissertation thesis, 2025. https://scholarworks.uark.edu/etd/5931