Back to search

Boston University

Biomechanics of short implants in the posterior mandible: titanium versus one- and two-piece zirconia implants

Abstract

dc:description.abstract

The present study investigated the biomechanical behavior of 1-piece and 2-piece zirconia implant systems in comparison with a conventional titanium implant configuration in the posterior mandible, with particular emphasis on implant–abutment interface mechanics, peri-implant bone loading, and stress propagation toward the inferior alveolar nerve (IAN). 3D finite element models were developed using a previously validated dentate mandibular model combined with high fidelity geometries of commercially available implant systems (obtained via μCT). Interface contact areas and internal gap volumes were quantified prior to biomechanical analysis, while progressive quasi-static occlusal loading was applied under physiological contact conditions. Stress distributions within the restorative components, surrounding bone, and IAN were evaluated using von Mises and maximum principal stress criteria according to the mechanical behavior of each material. The 2-piece zirconia system demonstrated approximately 70% lower implant–abutment contact area together with a 2.8-fold greater proportion of interfacial discontinuity compared with the titanium configuration, resulting in the highest internal stress concentrations, particularly at the implant–abutment interface. In contrast, the 1-piece zirconia configuration exhibited the most homogeneous stress distribution and the closest biomechanical response to the healthy dentition model within the peri-implant cancellous bone. Although all implant systems restored physiological bone-loading patterns to clinically acceptable levels, implant-supported restorations transmitted substantially greater residual stresses toward the IAN compared with natural dentition, with continuous elevated stress observed over clinically relevant implant-to-nerve distances. Within the limitations of the present finite element analysis, elimination of inter-component gaps through 1-piece zirconia configurations resulted in more favorable stress transfer behavior and reduced stress accumulation compared with 2-piece zirconia assemblies.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Design
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Restorative Sciences & Biomaterials
Grantor
Boston University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Alamro, Nawaf
Advisors dc:contributor.advisor
  • Tsouknidas, Alexandros
  • Michalakis, Konstantinos
ORCID dc:identifier.orcid

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivatives 4.0 International
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2144/53320

Chain of custody

source
Harvested from
Boston University
Base URL
open.bu.edu/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Alamro, Nawaf. Biomechanics of short implants in the posterior mandible: titanium versus one- and two-piece zirconia implants. masters thesis, Boston University, 2026. https://hdl.handle.net/2144/53320