Abstract
dc:description.abstractThe present study investigated the biomechanical behavior of 1-piece and 2-piece zirconia implant systems in comparison with a conventional titanium implant configuration in the posterior mandible, with particular emphasis on implant–abutment interface mechanics, peri-implant bone loading, and stress propagation toward the inferior alveolar nerve (IAN). 3D finite element models were developed using a previously validated dentate mandibular model combined with high fidelity geometries of commercially available implant systems (obtained via μCT). Interface contact areas and internal gap volumes were quantified prior to biomechanical analysis, while progressive quasi-static occlusal loading was applied under physiological contact conditions. Stress distributions within the restorative components, surrounding bone, and IAN were evaluated using von Mises and maximum principal stress criteria according to the mechanical behavior of each material. The 2-piece zirconia system demonstrated approximately 70% lower implant–abutment contact area together with a 2.8-fold greater proportion of interfacial discontinuity compared with the titanium configuration, resulting in the highest internal stress concentrations, particularly at the implant–abutment interface. In contrast, the 1-piece zirconia configuration exhibited the most homogeneous stress distribution and the closest biomechanical response to the healthy dentition model within the peri-implant cancellous bone. Although all implant systems restored physiological bone-loading patterns to clinically acceptable levels, implant-supported restorations transmitted substantially greater residual stresses toward the IAN compared with natural dentition, with continuous elevated stress observed over clinically relevant implant-to-nerve distances. Within the limitations of the present finite element analysis, elimination of inter-component gaps through 1-piece zirconia configurations resulted in more favorable stress transfer behavior and reduced stress accumulation compared with 2-piece zirconia assemblies.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Design
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Restorative Sciences & Biomaterials
- Grantor
- Boston University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Alamro, Nawaf
- Advisors dc:contributor.advisor
-
- Tsouknidas, Alexandros
- Michalakis, Konstantinos
- ORCID dc:identifier.orcid
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial-NoDerivatives 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/53320