Boston University
Expiration, collection, and storage: a multi-factor investigation of blood alcohol concentration
Abstract
dc:description.abstractA frequently encountered argument in impaired driving cases involving blood alcohol concentrations (BAC) is that ethanol (EtOH) levels may have been produced post-collection via microbial fermentation. Prior studies have independently refuted the effects of factors such as tube expiration status, collection method, and blood glucose level. This study, however, assessed the validity of these concerns collectively utilizing standard-issue 10 milliliter (mL) BD Vacutainer® Grey-Top Tubes containing 100 milligrams (mg) of sodium fluoride and 20 mg of potassium oxalate. Expired and unexpired blood collection tubes were compared under a variety of environmental conditions intended to simulate common collection scenarios. These scenarios involved following the recommended collection technique and leaving the tubes uncapped for 1 hour on a laboratory bench, in a restroom, or outdoors. Following exposure, the tubes were loaded with 5 mL of hyperglycemic leukocyte-reduced bank blood, with glucose levels in excess of 300 milligrams per deciliter (mg/dL), artificially spiked with EtOH to a target concentration of 0.08 grams/100 milliliters (gm%), and placed into one of the three storage conditions for two weeks: refrigerated at a temperature of 2 to 8 degrees Celsius (℃), room temperature at 20 to 25 ℃, and in a vehicle trunk with an outdoor temperature of, on average, 24.8 to 31.6 ℃. Upon completion of the two-week storage period, all samples were stored in a refrigerated storage vault prior to analysis to simulate real-world conditions. Three BAC measurements were performed on the samples: an initial baseline measurement before storage, a second analysis following the two-week storage period, and a final analysis after six and a half months of refrigerated storage. The results of this study indicate that there is no significant effect on BAC levels when using a 10 mL BD Vacutainer® tube past its expiration date. No de novo EtOH synthesis was detected; all ethanol-negative samples yielded non-detectable BAC measurements throughout the study. No significant differences in BAC levels were observed among the various simulated collection environments. The most significant decrease in EtOH concentration occurred in samples stored in the vehicle trunk, followed by those stored at room temperature; refrigerated samples showed the smallest decrease.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Biomedical Forensic Sciences
- Grantor
- Boston University
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Woolley, Roth Cook Sinclair
- Advisor dc:contributor.advisor
-
- Wareing, Celeste M
Subjects
dc:subject × 5Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/2144/53797