Back to search

State University of New York at Buffalo

Trace Mixture Analysis with Standoff Photothermal Cantilever Deflection Spectroscopy

Abstract

dc:description.abstract

Most chemical sensors work by collecting and transporting targeted chemicals for interaction with their sensing elements. When analyte molecules appear in very low concentrations, pre-concentrators are used for enriching the sample. This thesis describes a non-contact method which eliminates the need for time consuming pre-concentrator techniques for trace level chemical sensors. This technique combines the high selectivity of infrared spectroscopy with the high sensitivity of microcantilevers. The target molecules physisorbed on the surface are irradiated with tunable infrared radiation and the diffused reflected light is collected and focused on a thermally sensitive cantilever which bends sensitively as a function of the impinging IR beam intensity. The bending of the cantilever as a function of illumination wavelength therefore shows the IR absorption spectrum of the target molecules. Unlike in direct photothermal cantilever deflection spectroscopy, where physisorbed molecules on a bi-material cantilever are resonantly excited using tunable IR source for generating heat to bend the cantilever, the sensitivity of this method detailed in the present thesis is not limited by the area of the cantilever. To demonstrate the advantages, the non-contact IR spectra obtained with hazardous environmental chemicals and volatile organic compounds (VOC) are presented. It is shown that a limit of detection (LOD) of 4.5x1011 molecules/cm2 for deposited analytes can be achieved using the present method.

Degree

thesis:*
Grantor dc:publisher
State University of New York at Buffalo
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Leatt, Kyle; 0009-0009-1511-2340
Contributors dc:contributor
  • Thundat, Thomas
  • Chemical and Biological Engineering

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright retained by author. Users of works found in University at Buffalo Institutional Repository (UBIR) are responsible for identifying and contacting the copyright owner for permission to reuse. University at Buffalo Libraries do not manage rights for copyright-protected works and cannot assist with permissions.
Language dc:language
eng

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/10477/89964

Chain of custody

source
Harvested from
Buffalo
Base URL
ubir.buffalo.edu/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Leatt, Kyle; 0009-0009-1511-2340. Trace Mixture Analysis with Standoff Photothermal Cantilever Deflection Spectroscopy. State University of New York at Buffalo, 2024. http://hdl.handle.net/10477/89964