Abstract
dc:description.abstractThe wind flow over three buildings is simulated and presented for different wind directions using the standard k-ε turbulence model. The main purposes are, first, to predict the minimum wind load regions on roof mounted photovoltaic modules for reducing the cost of installing them on a mono-slope roof building. Secondly, to predict the flow fields along the gable of a tent roof building for analysis of the performance of a transverse axis wind turbine along the gable. The results for the cube simulation are compared with the experimental and other CFD results for validating the CFD. The present research provides the best locations for roof mounted PV modules. These results were significantly lower in magnitude than the NBCC values. The flow fields over the tent roof building were predicted and consistent with the field data. The flow over buildings was highly dependent on the building orientation and geometry.
Degree
thesis:*- Name thesis:degree_name
- Master of Science (MSc)
- Discipline thesis:degree_discipline
- Mechanical and Manufacturing Engineering
- Grantor dc:publisher.institution
- Graduate Studies
- Year dc:date.issued
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- REZA, MD. SHAMIM
- Advisor dc:contributor.advisor
-
- Wood, David
Subjects
dc:subject × 2Rights
dc:rights- Statement dc:rights
-
- University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
- Language dc:language.iso