Back to search

Graduate Studies

Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM)

Abstract

dc:description.abstract

Gastric motility and gastric emptying rates have been implicated in the symptoms of functional dyspepsia and gastroparesis. The current gold standard to assess gastric emptying is scintigraphy, which is limited by standardization and radiation concerns. This highlights the need for a novel method of assessing gastric motility. Transcutaneous Intraluminal Impedance Measurement (TIIM) is a novel method of assessing gastric motility. By measuring the dynamics of a known signal emitted from a battery-powered gastric retentive oscillator within the stomach, gastric motility can be quantified. In an eight-dog sham comparison study, TIIM was compared to force transducers implanted on the stomach. Two assessment metrics demonstrated statistically significant Pearson correlation coefficients between active TIIM pills and the force transducers (p<0.01, p<0.05), but not when TIIM pills were replaced by sham deactivated pills (p>0.1, p>0.1). A novel portable TIIM receiver was also proposed and tested in the lab to facilitate future ambulatory studies.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor dc:publisher.institution
Graduate Studies
Year dc:date.issued
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Poscente, Michael Dennis
Advisors dc:contributor.advisor
  • Mintchev, Martin
  • Yadid-Pecht, Orly
Committee members dc:contributor.committeemember
  • Bartley, Norman
  • Matyas, John
  • Murari, Kartikeya
  • Andrews, Christopher

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Poscente, Michael Dennis. Enhanced Electrogastrography Using Transcutaneous Intraluminal Impedance Measurements (TIIM). Graduate Studies, 2016. http://hdl.handle.net/11023/3201