Back to search

Graduate Studies

Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries

Abstract

dc:description.abstract

The anterior cruciate ligament (ACL) of the knee is one of the most frequently injured ligaments among young, athletic individuals. Previous research suggests that various anatomical factors contribute to both ACL tear incidence and predict changes in joint space width (JSW). However, investigation of simultaneous JSW with other anatomical measures tends to increase the imaging load required. Furthermore, each modality can include limitations such as small scanning region, high radiation dose, and weight-bearing tradeoffs. A recent addition to this field is bi-planar radiology (EOS Imaging) which offers simultaneous weight-bearing lateral and anterior views with novel low radiation exposure. The purpose of this study is to identify whether JSW measured by bi-planar imaging results in accurate and precise measurements of JSW. Our validation cohort of uninjured individuals (N=30, 26.7  5.1 years) underwent scanning to determine the short-term precision of the technique, involving two repeated scans per bi-planar radiograph and conventional tunnel view knee radiograph (4 scans total). The minimum apparent JSW was collected for each leg side and compartment. When the root mean square coefficient of variation (RMSCV) and least significant change (LSC) were measured, the bi-planar scans (RMSCV= 6.46%, LSC=1.07 mm) had improved or similar within scanner precision on average compared to conventional X-rays (RMSCV=7.66%, LSC=1.15 mm). When assessing the JSW accuracy by participants, there was a bias for higher JSW by bi-planar imaging than X-ray (p<0.01). Furthermore, the bi-planar standing position, performed with the left leg semi-weight-bearing, resulted in a significantly higher JSW measurement (p<0.01) in the left leg. This study emphasizes that while JSW measurements remain highly susceptible to variability, bi-planar scanners are highly reproducible. While radiography remains accessible clinically, accurate and precise JSW by bi-planar scanners is feasible provided knee position and alignment controlled.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Engineering – Biomedical
Grantor dc:publisher.institution
Graduate Studies
Year dc:date.issued
2023

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vandergaag, Isabella Derij
Advisor dc:contributor.advisor
  • Boyd, Steven
Committee members dc:contributor.committeemember
  • Walker, Richard
  • Manocha, Ranita
  • Edwards, Brent

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • University of Calgary graduate students retain copyright ownership and moral rights for their thesis. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Vandergaag, I. D. (2023). Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries (Master's/Doctoral thesis, University of Calgary, Calgary, Canada). Retrieved from https://prism.ucalgary.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Vandergaag, Isabella Derij. Validation of a novel imaging modality for knee joint space and lower limb alignment in acute knee injuries. Graduate Studies, 2023. https://hdl.handle.net/1880/117617