Back to search

Science

Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy

Abstract

dc:description.abstract

Stereotactic body radiation therapy (SBRT) is the standard of care to treat inoperable, early-stage non-small cell lung cancer. It delivers high doses of radiation to the target over a few fractions. This target is an expansion of the tissue-equivalent tumour into low-density tissue. Historically, lung SBRT treatments have been planned with the Analytical Anisotropic Algorithm. Recently, a newer and more accurate dose calculation algorithm, AcurosXB, has been introduced. This thesis characterizes the relationship between AcurosXB dose calculations and target density in the context of lung SBRT, with particular attention to cases where the added margin in an expanded target volume extends into very low-density lung tissue. Firstly, the superior accuracy of AcurosXB is established through dose calculation comparisons with Monte Carlo. Secondly, retrospective patient studies quantify the relationship between AcurosXB dose calculations and target density. Understanding this relationship enables future work to improve the dosimetry associated with lung SBRT.

Degree

thesis:*
Name thesis:degree_name
Master of Science (MSc)
Discipline thesis:degree_discipline
Physics & Astronomy
Grantor
Science
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moring, Mackenzie
Advisors dc:contributor.advisor
  • Morris, Donald
  • Kirkby, Charles
Committee members dc:contributor.committeemember
  • Morrison, Hali
  • Lim, Gerald
  • Cully, Christopher
  • Sun, Lingyue

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Unless otherwise indicated, this material is protected by copyright and has been made available with authorization from the copyright owner. You may use this material in any way that is permitted by the Copyright Act or through licensing that has been assigned to the document. For uses that are not allowable under copyright legislation or licensing, you are required to seek permission.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Citation
Moring, M. (2026). Influence of lung tissue heterogeneity on dose calculation in stereotactic body radiation therapy (Master's thesis, University of Calgary, Calgary, Canada). Retrieved from https://ucalgary.scholaris.ca.

Chain of custody

source
Harvested from
University of Calgary
Base URL
ucalgary.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Moring, Mackenzie. Influence of Lung Tissue Heterogeneity on Dose Calculation in Stereotactic Body Radiation Therapy. Science, 2026. https://hdl.handle.net/1880/125824