Acoustic and Hemodynamic Analysis of Phantoms: Roughness and Flow Dynamics

Abstract

dc:description.abstract

The purpose of this study was to determine whether different vascular phantoms, with and without a surrogate arm, could serve as effective analogs to the human brachial artery for assessing endothelial dysfunction, an early indicator of cardiovascular disease, particularly atherosclerosis. Atherosclerosis is characterized by plaque buildup and endothelial damage, which precede more severe clinical events and are often detectable through changes in vascular function. A 40” water tower was used to simulate diastolic pressure, enabling water flow through each phantom. Strain gauge pressure transducers were placed at both ends of the phantoms to measure pressure drop, while a microphone captured the sound profile of the flow. The sound was expected to vary between phantoms due to differences in their luminal endothelial linings, which affect Reynolds number and, consequently, friction factor and pressure drop. To analyze the sound data, a Fast Fourier Transform (FFT) was applied to convert time domain signals into the frequency domain. A two factor ANOVA was then conducted to evaluate the effects of two variables: the presence of a surrogate arm and the type of vascular phantom. Results showed that both the type of phantom and the presence of the surrogate arm had statistically significant effects on the measured parameters. These findings suggest that this prototype system holds promise for non-invasive clinical evaluation of endothelial dysfunction and early-stage atherosclerosis, potentially enabling earlier diagnosis and treatment, when intervention is most effective, thereby improving patient outcomes and saving lives.

Degree

thesis:*
Name thesis:degree_name
MS in Biomedical Engineering
Discipline thesis:degree_discipline
Biomedical Engineering

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sundberg, Ethan Erik Olof
Contributors dc:contributor
  • Michael Whitt
  • Biomedical Engineering
  • College of Engineering

Subjects

dc:subject × 11

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.calpoly.edu/theses/3067

Chain of custody

source
Harvested from
Cal Poly
Base URL
digitalcommons.calpoly.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Sundberg, Ethan Erik Olof. Acoustic and Hemodynamic Analysis of Phantoms: Roughness and Flow Dynamics. https://digitalcommons.calpoly.edu/theses/3067