Back to search

Department of Electrical Engineering

The development of an on-chip-metering solution

Abstract

dc:description.abstract

Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 specifications.

Degree

thesis:*
Grantor dc:publisher.institution
Department of Electrical Engineering
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kaplen, David
Advisor dc:contributor.advisor
  • Tapson, Jonathan

Subjects

dc:subject × 1

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Dc Identifier Apacitation
Kaplen, D. (2001). <i>The development of an on-chip-metering solution</i>. (Thesis). University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering. Retrieved from http://hdl.handle.net/11427/9735
Dc Identifier Chicagocitation
Kaplen, David. <i>"The development of an on-chip-metering solution."</i> Thesis., University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735
Dc Identifier Citation
Kaplen, D. 2001. The development of an on-chip-metering solution. University of Cape Town.
Dc Identifier Ris
TY - Thesis / Dissertation AU - Kaplen, David AB - Energy Measurements Ltd (EML), a joint venture partnership between Siemens and Spescom, manufacture prepaid electricity utility meters for both the local and international markets. Under the brand name CASHPOWER 2000, EML produces single and polyphase prepayment utility meters. Currently, these meters currently utilise a separate module for the measuring of electrical energy. In order to reduce component costs, EML proposed the energy measurement be conducted by the onboard Microcontroller Unit (MCU), a term known as On-Chip-Metering (OCM). It is envisioned that this would quickly translate in an increase in revenue. However, a major concern regarding this has been the increase in the required processor overhead. The CASHPOWER 2000 embedded MCU would be required to conduct all the present metering functionality in addition to the energy measurement. This, together with the cost analysis and compliance with the stipulated IEC1036 regulations, constitute the key criteria in determining the projects viability. This dissertation represents the investigative and development stages of a prototype algorithm and accompanying peripheral hardware as a possible solution for OCM. As part of the preliminary research, several examples of digital power and energy-measurement techniques were investigated. A comparative analysis of these was performed to facilitate the development of a unique solution based on the research conducted. This completed, a prototype was developed and preliminary testing was conducted to determine its compliance with the stipulated regulations for a class 2 meter, as per IEC1O36 specifications. DA - 2001 DB - OpenUCT DP - University of Cape Town LK - https://open.uct.ac.za PB - University of Cape Town PY - 2001 T1 - The development of an on-chip-metering solution TI - The development of an on-chip-metering solution UR - http://hdl.handle.net/11427/9735 ER -
Dc Identifier Vancouvercitation
Kaplen D. The development of an on-chip-metering solution. [Thesis]. University of Cape Town ,Faculty of Engineering & the Built Environment ,Department of Electrical Engineering, 2001 [cited yyyy month dd]. Available from: http://hdl.handle.net/11427/9735

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kaplen, David. The development of an on-chip-metering solution. Department of Electrical Engineering, 2001. http://hdl.handle.net/11427/9735