Quantitative Multiplexed Multi-pinhole Small-Animal SPECT

Abstract

dc:description.abstract

Small-animal microSPECT is an important research tool for the development of clinical diagnostic tests, evaluation of novel pharmaceuticals, and basic science research. Experimentally quantifying the accuracy of microSPECT — the reproducibility of measurements made using microSPECT, and how well the reconstructed microSPECT data correlates to the true tracer distribution — is therefore essential. Photon attenuation and scatter complicate the problem of acquiring quantitatively accurate information from SPECT.In this work, the reproducibility of cardiac measurements made in rats using the nanoSPECT/CT scanner (Bioscan, Washington, DC) is first evaluated without scatter or attenuation correction. For relative perfusion measurements of rat myocardia, normal databases for 99mTc-tetrofosmin and 201Tl imaging are created and it is shown that the relative myocardial perfusion measurements made using either tracer are reproducible over repeated scans and over multiple rats with standard deviations of 3% and 4% respectively.Attenuation and scatter compensation are implemented in the SPECT reconstruction algorithm to evaluate the accuracy of using nanoSPECT to recover absolute tracer concentrations in phantoms and in vivo. With attenuation and scatter compensation, absolute tracer concentration is measured using SPECT images with systematic and random uncertainties as low as 1% in phantoms, relative to dose calibrator measurements. The systematic and random uncertainties for measurements of total cardiac tracer uptake in vivo compared to well chamber measurements ex vivo were as small as –1% and 3% respectively.Reevaluation of the reproducibility of the cardiac measurements with attenuation and scatter correction demonstrates that neither correction strongly influences the relative perfusion measurements or their reproducibility. However, it is shown that attenuation correction does significantly modify the relationship between body weight and absolute tracer uptake.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Physics - Medical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Strydhorst, Jared

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright © 2013 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Strydhorst, Jared. Quantitative Multiplexed Multi-pinhole Small-Animal SPECT. Doctoral thesis, Carleton University, 2013. https://hdl.handle.net/20.500.14718/38361