The study of traumatic brain injury is critical to the improvement of protective equipment. Numerical models of brain deformation require real-world data for validation. In preparation for upcoming cadaver studies, a novel method of measuring displacement and strain fields of optically inaccessible internal planes using high-speed X-ray, embedded contrast markers and digital image correlation (DIC) is presented herein. An uncoupled scintillator and optimally-selected high-speed camera enable continuous X-ray imaging through a human head at 10,000 fps. As varying composition creates radiographic contrast, contrast within a human brain is limited, therefore, artificial contrast markers are required. Markers must be dynamically coupled to the bulk material and provide sufficient X-ray contrast. An analytical tool was developed to design of contrast markers. The impact of contrast-to-noise ratio and out-of-plane motion on DIC accuracy were quantified. Finally, a feasibility study using a biofidelic headform subjected to a NOCSAE drop test is presented.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Mechanical
Grantor dc:publisher
Carleton University
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Magnan, Stephane

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2018 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Magnan, Stephane. Analysis of Radiographic Contrast Markers for X-ray Digital Image Correlation of Tissue-Simulants Under Dynamic Load. Master's thesis, Carleton University, 2018. https://hdl.handle.net/20.500.14718/38825