Development of a Hygrothermal Model Validation Methodology Using a Two-Storey Guarded Hot Box

Abstract

dc:description.abstract

Hygrothermal performance is an essential component of building performance, with heat, air, and moisture transport through the building envelope as a key element. Current modelling programs such as Delphin can be used to simulate hygrothermal performance of building envelopes but require physical data for validation, either from in-situ or controlled laboratory experiments. This allows for confidence in the use of hygrothermal models. This thesis used a two-storey guarded hot box (GHB) apparatus to develop a testing sequence that provided sufficient data for confidence in validation. Two lightweight vertical walls were tested in the GHB, each for 1200 hours. The model validation was completed using graphical and statistical analysis. After an initial validation, model adjustments were completed based on the sensitivity of various model parameters. The improved models resulted in excellent agreement between the experimental and modelled performance.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Sustainable Energy
Grantor dc:publisher
Carleton University
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hilbrecht, Robin Frances

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2024 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Hilbrecht, Robin Frances. Development of a Hygrothermal Model Validation Methodology Using a Two-Storey Guarded Hot Box. Master's thesis, Carleton University, 2024. https://hdl.handle.net/20.500.14718/42119