Back to search

Carleton University

Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer

Abstract

dc:description.abstract

Tissue equivalent proportional counters (TEPCs) are recognized as standard instrument for cosmic radiation dose measurement because it can separate gamma and neutron spectra in mixed field microdosimetry. HAWK TEPC was employed in the project as a reference instrument to measure the cosmic radiation exposure in terms of dose equivalent and ambient dose equivalent at ground level, calibrate and compare the doses obtained from the analytical model based on Excel-based Program for Calculating Atmospheric Cosmic Ray Spectrum (EXPACS) and the overflow channel of Canada's Fixed Point Surveillance (FPS) spectrometer. The process of understanding the performance of TEPC as well as designed experiments for cosmic radiation dose measurement done at 8 different locations were presented. Experimental doses obtained with TEPC is consistent with the analytical results, the minimum and maximum discrepancies are 3.8 % and 26.8 % respectively. The work will be further evaluated and applied to other FPS stations.

Degree

thesis:*
Name thesis:degree_name
Master of Science (M.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Physics
Grantor dc:publisher
Carleton University
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ma, Haiqian

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2022 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, research, scholarship, and teaching. Theses may only be shared by linking to Carleton University Institutional Repository and no part may be used without proper attribution to the author. No part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ma, Haiqian. Application of Tissue Equivalent Proportional Counter (TEPC) in Intercalibration with NaI (Tl) Spectrometer. Master's thesis, Carleton University, 2022. https://hdl.handle.net/20.500.14718/42293