Back to search

Carleton University

Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications

Abstract

dc:description.abstract

Permittivity spectroscopy measures a material’s electromagnetic response across a frequency range, typically using an open-ended coaxial probe. The process involves transmitting an electromagnetic wave through the probe toward the material under test (MUT). While portion of the wave radiates into the material, the remainder reflects back due to the impedance mismatch at the probe’s aperture. Accurately determining the MUT permittivity requires precise modelling of the electromagnetic wave propagation within the probe, but current methods have notable limitations: 1) balancing accuracy and efficiency remains challenging, with one often sacrificed for the other, 2) most models assume single-layer MUTs, and 3) accurate models for needle-shaped probes, such as bevelled or conical shapes, are lacking. This thesis addresses these challenges with three main contributions. First, it introduces a closed-form, full-wave model reduced to a simple matrix multiplication. The model has been validated experimentally using two coaxial probes and four reference liquids. It exhibited an average error of 4.35%, which is similar to or better than state-of-the-art models, while being 98% faster Second, it proposes a model for calculating the permittivity of a two-layer MUT. The proposed method is validated experimentally in two different scenarios within a frequency range of 1 GHz to 5 GHz. The average error of the extracted permittivity from the inverse problem is 1.08%, and the average error in the extracted distance is 10 μm. Lastly, this thesis introduces a model for bevelled and conical probes that can penetrate tissue for in-vivo measurements. The accuracy of the model is validated using experimental measurements on water, with a relative error of less than 1%. Overall, these models represent an important step toward establishing permittivity spectroscopy as a next-generation diagnostic modality.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Engineering, Electrical and Computer
Grantor dc:publisher
Carleton University
Year dc:date.issued
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Asilian Bidgoli, Hossein

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright © 2025 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Asilian Bidgoli, Hossein. Modelling of Open-Ended Coaxial Probes for Real-Time Dielectric Spectroscopy in Biomedical Applications. Doctoral thesis, Carleton University, 2025. https://hdl.handle.net/20.500.14718/43931