Back to search

Carleton University

Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device

Abstract

dc:description.abstract

This thesis investigates signal acquisition and physiological parameter extraction in a compact multisensor handheld cardiac monitor, integrating electrocardiography (ECG) and photoplethysmography (PPG). The use of dry-contact ECG leads is assessed for its impact on signal quality. An electrode spacing of 7mm is recommended to minimize the number of missed beats. Although reduced inter-electrode spacing decreases QRS amplitude, a robust Pan–Tompkins beat detection algorithm can still detect beats for the calculation of Heart Rate and Heart Rate Variability under various noise conditions. A two-Gaussian modeling framework is proposed with iterative Gaussian decomposition for single-cycle PPG morphology analysis. The method enables robust extraction of systolic and diastolic features, including dicrotic notch timing and augmentation index, for simulated Sand clinical data. The model is evaluated in longitudinal PPG analysis, enabling beat-to-beat morphological tracking. Together, these contributions establish an integrated, signal-aware framework to assist in remote cardiac monitoring systems.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science (M.App.Sc.)
Level thesis:degree_level
Master's
Discipline thesis:degree_discipline
Engineering, Electrical and Computer
Grantor dc:publisher
Carleton University
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Forster, Phillippe

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright © 2026 the author(s). Theses may be used for non-commercial research, educational, or related academic purposes only. Such uses include personal study, distribution to students, research and scholarship. Theses may only be shared by linking to the Carleton University Institutional Repository and no part may be copied without proper attribution to the author; no part may be used for commercial purposes directly or indirectly via a for-profit platform; no adaptation or derivative works are permitted without consent from the copyright owner.
Language dc:language.iso
en

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Carleton University
Base URL
carleton.scholaris.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Forster, Phillippe. Signal Modelling and Physiological Parameter Extraction for a Multisensor Handheld Cardiac Monitoring Device. Master's thesis, Carleton University, 2026. https://hdl.handle.net/20.500.14718/45268