Back to search

Colorado State University. Libraries

A system for detecting fluorescent tracers in streamflow

Abstract

dc:description.abstract

A system is developed capable of continuously monitoring the relative concentration of a fluorescent tracer in streamflow. Streamside instrumentation automatically registers stream-borne tracer concentrations as a function of time on a gelatin-coated film. The film is routed through a device which passes a continuous sample-aliquot diverted from the tracer-dosed stream over a small segment of the film. The "exposed" film is periodically gathered from stream sites and analyzed in a laboratory-based fluorometer. Utility of the system is studied for the gaging of streamflow to produce a hydrograph, to measure stream discharge instantaneously, and to determine time-of-stream-travel. Hydrographs resulting from 640 hours of gaging two Colorado mountain streams with the system are compared to those obtained from closely located sharp-crested weirs. The maximum instantaneous deviation between hydrographs reaches 10% and average absolute departure equals 1.8%, while algebraic departure averages +0.3%. The practicality of using this system to obtain time-of-stream travels is demonstrated for five Colorado mountain streams. A total of 62 traveling tracer-clouds are registered on gelatin-coated film, from which time-of-stream-travels are determined. Processes involved in the system and factors affecting its precision are investigated. Theoretical and experimental evidence strongly indicates that the bulk of tracer uptake by gelatin follows processes that are physical rather than chemical in nature. Stream temperature changes and duration of film-tracer contact are the two most important factors affecting precision of the system. Neither major factor caused any unsolvable problem when field operations were standardized. The system will have utility in operations where an expensive, temperature-sensitive fluorometer can not be stationed stream-side, and where the particular objectives of stream measurements do not justify the cost of conventional techniques, but where fair accuracy and continuous records of short to moderate duration are desired.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (Ph.D.)
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Watershed Sciences
Grantor dc:publisher
Colorado State University. Libraries
Year dc:date.issued
1970

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Steppuhn, Harold Wolfgang, author
  • Meiman, James R. (James Richard), advisor
  • Dils, Robert E., committee member
  • Harris, David V., committee member
  • Johnson, Gestur, 1910-, committee member
  • Duke, Harold R. (Harold Ray), 1940-, committee member

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright and other restrictions may apply. User is responsible for compliance with all applicable laws. For information about copyright law, please see https://libguides.colostate.edu/copyright.
  • This Item is protected by copyright and/or related rights (https://rightsstatements.org/vocab/InC/1.0/). You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
eng, English

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
Colorado State University
Base URL
api.mountainscholar.org/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Steppuhn, Harold Wolfgang, author; Meiman, James R. (James Richard), advisor; Dils, Robert E., committee member; Harris, David V., committee member; Johnson, Gestur, 1910-, committee member; Duke, Harold R. (Harold Ray), 1940-, committee member. A system for detecting fluorescent tracers in streamflow. Doctoral thesis, Colorado State University. Libraries, 1970. https://hdl.handle.net/10217/234093