Back to search

Cornell University

Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates

Abstract

dc:description.abstract

Floc blankets are used in water treatment plants to improve plant performance and aid in sludge removal and consolidation. Maintaining a fully functioning floc blanket in sedimentation tanks requires that the floc blanket remain fluidized and sludge prevented from building up on the bottom of the tank. A laboratory water treatment system was used to evaluate the range of energy dissipation rates (EDR) of the inlet to the sedimentation tank to determine when the settled effluent turbidity of the system would exceed drinking water quality standards.. Increasing the inlet jet EDR up to approximately 300 mW/kg did not increase effluent turbidity of the system. Small inlet jets with high EDR can be used to ensure resuspension of the floc density current without adversely affecting water treatment plant performance. The design of flocculators is based on mean shear (G) and hydraulic residence time (θ) and the product (Gθ). Guidelines for these values are conservative and designs outside the suggested range could lower plant capital costs. The following flocculator parameters were evaluated: 1) increasing G (range of 74-251 s-1) while decreasing θ from 269 to 80 s (maintaining a constant Gθ) and 2) maintaining a constant G (72 s-1) and varying θ (24 to 1425 s). Flocculator θ below recommended design guidelines performed well indicating that shorter flocculators could be used in the presence of floc blankets. Three potential hypotheses by which residual particles aggregate with other flocs in the floc blanket were considered: residual particles aggregate with 1) other residual particles, 2) small flocs (transitional), or 3) large flocs (hindered). Three coagulant doses (0.625, 1.25, and 2.5 mg/L) were tested with four hydraulic flocculators with constant Gθ but varying G (72, 126, 251, and 340 s-1) and θ (269, 159, 102, and 59 s) on the combined system. A classification system of flocs in the floc blanket was defined based on floc size and time-scale. Results strongly suggest that hypothesis 2 is valid, however, research is needed on floc sizes at specific locations within the system.

Degree

thesis:*
Name thesis:degree_name
Ph. D., Civil and Environmental Engineering
Level thesis:degree_level
Doctor of Philosophy
Discipline thesis:degree_discipline
Civil and Environmental Engineering
Grantor
Cornell University
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Garland, Casey Ann
Chair dc:contributor.chair
  • Lion, Leonard William
Committee members dc:contributor.committeemember
  • Desjardins, Olivier
  • Cowen, Edwin Alfred, III
  • Weber-Shirk, Monroe

Subjects

dc:subject × 5

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Bibid
10361666
Dc Identifier Other
ProQuest Submission ID: 10372
ProQuest Publication ID: 10605545

Chain of custody

source
Harvested from
Cornell University
Base URL
ecommons.cornell.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Garland, Casey Ann. Uncovering the mysteries of the floc blanket: an exploration with inlet jets, flocculators, and polyaluminum chloride precipitates. Doctor of Philosophy thesis, Cornell University, 2017. https://hdl.handle.net/1813/56989