Back to search

Cranfield University

Masking the problem - Human errors in qualitative respiratory equipment fit testing

Abstract

dc:description.abstract

Respiratory protective devices are designed to protect wearers from inhalation hazards in the workplace. The performance of tight-fitting devices relies on a good face-to-facepiece seal, and this is tested through a prescribed procedure known as a ‘fit test’ which provides an assessment of face seal leakage using either a quantitative or qualitative detection method. Numerous anecdotal reports exist about human errors in workplace application of the qualitative fit test method, but published research is limited to laboratory-based studies. This thesis provides the first investigation of real-world human errors in qualitative fit testing and proposes measures to improve the reliability of this widely used fit test method. Through an extensive literature review, the study examines the multi-faceted body of current research and identifies a major research gap in the knowledge pertaining to human errors. An assessment of the prevalence and sources of human errors in qualitative fit testing is conducted through secondary analysis of data acquired during Fit2Fit practical assessments. Findings provide information about the types of errors made by real-world fit testers, trends over time, and differences between Fit2Fit accredited and non-accredited fit testers. Through a theoretical analysis of the fundamental method principles, this thesis postulates a set of ‘critical errors’ which have the potential to undermine the reliability of the test. An empirical assessment of the impact of critical errors is conducted through a series of aerosol concentration studies and live shortened fit tests. When these impacts are applied to secondary data of errors made by real-world fit testers, this thesis offers the first estimate of a workplace (Beta) error value for this fit test method. Through examination of current control measures, this thesis highlights gaps in current resources, and proposes a set of engineering and administrative solutions which aim to address critical errors and improve workplace safety.

Degree

thesis:*
Grantor dc:publisher
Cranfield University
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Long, Karen M
Advisors dc:contributor.advisor
  • Mai, Nathalie
  • Williams, Michael

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © Cranfield University, 2022. All rights reserved. No part of this publication may be reproduced without the written permission of the copyright holder.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Repository record dc:identifier.uri
https://dspace.lib.cranfield.ac.uk/handle/1826/25333

Chain of custody

source
Harvested from
Cranfield University
Base URL
dspace.lib.cranfield.ac.uk/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Long, Karen M. Masking the problem - Human errors in qualitative respiratory equipment fit testing. Cranfield University, 2022. https://dspace.lib.cranfield.ac.uk/handle/1826/25333