Back to search

Duke University

Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy

Abstract

dc:description.abstract

<p>Laser lithotripsy (LL) is the gold-standard treatment for kidney stones; however, its clinical efficacy remains limited by the lack of real-time, quantitative feedback regarding the mechanical energy delivered to the stone. Currently, urologists rely primarily on subjective visual estimation through endoscopy, which is often obscured by debris and offers no depth-resolved information. This dissertation presents the development of an integrated three-dimensional passive cavitation mapping (3D-PCM) platform designed to provide non-invasive, real-time, and super-resolved monitoring of laser-induced cavitation activities.The research progresses through three major stages of innovation. First, a first-generation 3D Super-Resolution PCM (3D-SRPCM) framework was established. By implementing a radial symmetry localization algorithm, the system surpassed the acoustic diffraction limit, achieving sub-millimeter spatial precision. Through multimodal validation with high-speed imaging and optical coherence tomography (OCT), "Accumulated Impact Pressure" (Acc IP) was identified and validated as a robust quantitative biomarker ( γ =0.93) for predicting volumetric stone damage. Second, to address the computational demands of intraoperative monitoring, a GPU-accelerated beamforming architecture was developed. By optimizing sparse-matrix multiplication, the reconstruction latency was reduced to under 1 ms, enabling the spatiotemporal decoupling of complex cascading cavitation events. To further bridge the gap to clinical application, a custom 5 MHz, 256-element planar 2D matrix array was engineered. This second-generation hardware provides a deep field-of-view (FOV) exceeding 100 mm, ensuring consistent functional localization in deep-seated human tissues. Finally, the platform was translated into a pre-clinical swine model. To combat physiological motion, the transducer was integrated with a multi-axis robotic arm governed by a closed-loop automatic repositioning algorithm. This system dynamically tracks the target stone using real-time 3D-PCM feedback, ensuring optimal acoustic coupling throughout the surgery. The results demonstrate that the integrated platform can accurately reconstruct surgical trajectories and provide intuitive, color-coded feedback on therapeutic efficacy. Collectively, this work provides a foundational engineering framework for the next generation of "navigation-guided" intelligent lithotripsy systems, promising to enhance surgical precision and patient safety in urology. </p>

Degree

thesis:*
Department dc:contributor.department
Biomedical Engineering
Year dc:date.issued
2026

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Li, Daiwei
Advisor dc:contributor.advisor
  • Yao, Junjie

Subjects

dc:subject × 1

Rights

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10161/35711

Chain of custody

source
Harvested from
Duke University
Base URL
dukespace.lib.duke.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Li, Daiwei. Three-dimensional Passive Cavitation Mapping during Laser Lithotripsy. 2026. https://hdl.handle.net/10161/35711