Back to search

École de technologie supérieure

Development and validation of the control loops for the haptic interfaces of a standard manual wheelchair simulator

Abstract

dc:description

There are about 47,000 manual wheelchair (MWC) users in Quebec, and 155,000 in Canada. Research indicates that 30 to 70% of them begin feeling chronic pain in the upper limb joints within the first five years of use. To investigate this issue in the laboratory, our team has developed a manual wheelchair simulator that uses instrumented wheels as force sensors. These wheels replace the wheelchair’s original wheels, thus limiting the degree of realism of the simulator. The objective of this work was to increase this degree of realism, by replacing the force sensors used currently. To this effect, a six-axes force cell was placed underneath the wheelchair. An admittance control loop was developed to control the moment-velocity interaction of the wheelchair’s rear wheels. Data gathering was conducted with one healthy subject to evaluate the level of realism of wheelchair propulsion. On both sides, maximum propulsive moments Mzmax (Nm), maximum applied force FTOTmax (N), push time PT (s) and recovery time RT (s) were calculated and compared between three conditions: on the ground (OG), on the simulator controlled by the instrumented wheels (SW) and on the simulator controlled by the force cell (FC). Results confirm the research hypotheses: the control loop is stable, meaning that the real speed follows the desired speed. Comparison of biomechanical parameters is as follows: regarding Mzmax, the difference between conditions OG and FC is small, whereas that between OG and SW is large. With regards to FTOTmax and TP, differences between OG and FC, and between OG and SW are both large. For TR, differences between OG and FC and between OG and SW are both small. In conclusion, it seems that propulsion on the simulator controlled by a force cell may be slightly closer to propulsion on the ground than that on a simulator controlled by instrumented wheels. This could be explained by the fact that the movement of the trunk of the user affects the dynamics of the wheelchair-user system. This effect is captured by the force cell, but not by the Smartwheels.

Degree

thesis:*
Name thesis:degree_name
Mémoire de maîtrise électronique
Level thesis:degree_level
masters
Grantor dc:publisher
École de technologie supérieure
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pizarro-Chong, Ary Druva

Subjects

dc:subject × 1

Rights

Language dc:language
en

Identifiers

dc:identifier.*
Identifier
INSERT-YOUR-LIBRARY-ID-HERE2713

Chain of custody

source
Harvested from
ETS (Quebec)
Base URL
espace.etsmtl.ca/cgi/oai2
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Pizarro-Chong, Ary Druva. Development and validation of the control loops for the haptic interfaces of a standard manual wheelchair simulator. masters thesis, École de technologie supérieure, 2021.