Freie Universität Berlin
Preparation and characterization of drug-loaded (meth)acrylic intraocular lenses
Abstract
dc:description.abstractNowadays, the cataract surgery is the most often performed surgery worldwide and considering the demographic changes, the incidence of age-related cataract is expected to increase further. In the developing countries, cataract is still the main cause for blindness but as the health system improves, the number of cataract surgeries is steadily increasing. During the surgery, the clouded natural lens is removed and replaced by an artificial intraocular lens (IOL), which consists out of the optical part and small anchors that localize the lens within the eye, named haptic. Although postoperative complications are rare, patients have to apply eye-drops or ointments frequently (every 2 - 4 hours in the first week) due to the very poor bioavailability of topical ophthalmica. This results in low patient compliance, especially among elderly people. Different drug delivery systems (DDS) for the posterior eyeball have been investigated recently, however, none of these DDS reduced the need for additional topical drug instillations. Therefore, a better medical treatment is highly desired for patients, who have undergone a cataract operation. It has been suggested, that the inserted intraocular lenses could be used as a potential vehicle for drug delivery and would release the API directly to the targeted tissues. Furthermore, drug-eluting lenses could maintain sustained drug release. The cataract surgery and intraocular lenses have been steadily improved for almost 70 years and the development of the drug-eluting lenses is the next step in this ongoing evolution. This research project focused on the development of drug-loaded intraocular lenses in order to avoid frequent drug administrations after cataract surgeries and to reduce postoperative complications, such as infections and inflammations. Therefore, extended drug release of antibiotics and steroids was targeted, while it was essential to preserve perfect optical properties of the IOLs. Besides the 100% light transmittance, high refractive indexes were desired as well as the flexibility of IOLs needed to be preserved in order to facilitate lens insertion in a folded manner. In order to resemble common commercialized IOLs, various formulations of hydrophilic, hydrophobic and amphiphilic IOLs were prepared by polymerization of various acrylates and methacrylates. All prepared lenses were characterized and had comparable physical and chemical properties to the marketed IOLs. Hydrophilic lenses were either prepared by bulk-polymerization of solely 2-hydroxyethyl methacrylate (HEMA) or in a mixture with the hydrophobic methyl methacrylate (MMA) (20%, w/w). Hydrophilic IOLs swelled in water and formed hydrogels. Thus, the refractive index of pure poly-HEMA lenses, 1.4200, was improved to 1.4500 with increasing amount of MMA in the composition due to the reduced water uptake (50% - 30%). The drug loading for hydrophilic lenses was achieved by soaking in aqueous drugs solutions and was affected by various factors such as the API solubility, the drug concentration in the soaking media, the soaking time and the lens polymer composition. To increase soaking efficiency, the soaking media was replaced by ethanol, as a low toxic organic solvent. By using ethanol as soaking solvent, increased drug loadings, also for less water-soluble drugs, were achieved. After soaking, ethanol was removed by drying in a vacuum oven, and optical properties of the drug-loaded lenses were preserved perfectly. In a dry state hydrophilic methacrylates were brittle, however, initial lens shape and flexibility were restored and ensured after lens rehydration, due to the plasticizing effect of incorporated water. Therefore, lens rehydration in biocompatible medium should be performed prior to its surgical insertion to the patient. To prepare hydrophilic lenses, loaded with two drugs simultaneously, IOLs were soaked in ethanolic dexamethasone solution followed by drying. Further, the rehydration was performed in aqueous drug (sodium salicylate) solution and thereby, the second drug was loaded. By prolonging the rehydration from 1 hour to 5 hours, the sodium salicylate loading was increased slightly from 0.55 ± 0.05% to 0.62 ± 0.01% for pure HEMA lenses and was almost doubled from 0.24 ± 0.01% to 0.40 ± 0.01% for polymers, containing 20% MMA. However, longer soaking/rehydration times decreased the dexamethasone loading from 0.57 ± 0.05% to 0.47 ± 0.01% and from 0.88 ± 0.01% to 0.87 ± 0.01% for both formulations, due to dexamethasone release into the rehydration media. In comparison to IOLs, prepared solely by HEMA, IOLs, containing 20% of the hydrophobic methyl methacrylate, had a slower drug uptake and consequently slower release, caused by a slower drug diffusion, attributed to the lower water content. Furthermore, simultaneous drug release was observed from IOLs; the diffusion driven release of dexamethasone was strongly extended (t80%: 14 days) due to its low water solubility compared to the better soluble sodium salicylate (t80%: 1 day). To avoid the premature drug release during rehydration, lenses were loaded in ethanolic drug solutions, containing diclofenac sodium, dexamethasone or both APIs simultaneously. Drug loadings were close to 2% for both APIs in single- and in dual-loaded lenses. After the ethanol removal, the rehydration was performed within 30 minutes in saturated aqueous drug solutions to avoid drug release, while restoring the flexibility of the lenses. In single-loaded intraocular lenses, diclofenac sodium was released faster (t80%: 72 hours) than dexamethasone (t80%: 16 days), attributed to its higher water solubility. In dual-loaded lenses, diclofenac release rate was comparable to the single-loaded formulation, while dexamethasone release was accelerated. The additional loaded hydrophilic drug increased the osmotic pressure within the lens, causing a higher water uptake, which resulted in more dissolved dexamethasone within the water phase of the hydrogel and thereby a faster drug release. In DSC, there were no melting peaks observed in the dried drug-loaded IOLs, whereas the Tg was decreased, suggesting that drugs were monomolecularly dispersed and had plasticizing properties. Transparency of all lenses was confirmed during and after the drug release. A specific two chamber device was suggested, in order to supply drug-loaded intraocular lenses in a dry state for improved product stability. The dried lens was stored in the first chamber, whereas the second chamber contained the rehydration/loading media. By releasing the IOL into the second chamber, the rehydration was accomplished in the same device and thus, the risk of contaminations was reduced. Therefore, hydrophilic lenses already loaded with poorly soluble drugs could be delivered to the physicians in the dry state, requiring just a short rehydration, accomplished by the same packaging device 30 minutes before the surgery. Nowadays, hydrophobic acrylates are the most common IOL materials due to their high refractive index (1.4900 – 1.5500) and less frequent postoperative complications. Homopolymers of polymethyl methacrylate (PMMA) and polyphenoxyethyl acrylate (pPOEA) were prepared and characterized as an example of commercially available hydrophobic lenses. In contrast to hydrophilic lenses, sufficient drug loadings for hydrophobic IOLs could not be achieved by soaking in aqueous drug solutions, due to the insufficient water penetration into the lens matrix (< 0.5%). Although, higher drug loadings were achieved with organic solvents, drug release in aqueous medium was very low, due to the low drug diffusion within the lens polymers. When the polymer compositions were modified to improve the drug diffusion, the optical quality of lenses decreased extremely. Therefore, external drug delivery systems were investigated and lenses were either coated at the lateral surface of the optical part or at the haptic. Different coating patterns were examined. When the coating was applied on the lateral surface of the IOLs, the required foldability of IOLs could be preserved and the optical parts in the center of the intraocular lenses remained untreated. Therefore, 100% light transmittance was ensured. The PLGA was used as a biodegradable polymer for dexamethasone coatings and zero-order release kinetics for various drug loadings were successfully achieved. Furthermore, the two coating areas were divided and could be tuned for different drugs completely independently. Therefore, applied coatings were adjusted with respect to the drug solubility, the drug loading, the PLGA and the coating level in order to obtain release patterns with the desired performances. Hence, minocycline, as a model antibiotic drug was released within one week and dexamethasone as a glucocorticoid was eluted within one month, from a single IOL formulation. The coating adhesion on the hydrophobic intraocular lenses was good and after the completed PLGA degradation, these lenses had identical properties as the non-coated lenses. Amphiphilic lenses combined the advantages of hydrophilic and hydrophobic lenses. While hydrophilic lenses could be loaded by soaking methods, hydrophobic lenses presented a higher refractive index, the drug release was more extended and foldability was provided, also in the dry state. Therefore, three different lens polymers were prepared, containing hydrophilic (hydroxyethyl methacrylate, hydroxybutyl methacrylate, and hydroxyethyl acrylate) and hydrophobic (butyl methacrylate, ethyl acrylate, isobutyl methacrylate and phenoxyethyl acrylate) monomers in different ratios. The drug loading by soaking in ethanolic dexamethasone solution was evaluated and the drug release was strongly extended (t80%: 190 – 240 days), due to limited water content within the polymer matrix (2.03 ± 0.34% - 4.57 ± 0.36%) and drug-polymer interactions. Dexamethasone precipitated within some lens polymers leading to decreased light transmittance. Therefore, a lens polymer composition was optimized and the ratio of monomers was tuned in order to improve the drug loadings, release patterns, the refractive index and the flexibility of intraocular lenses. In order to ensure 100% light transmittance for IOLs which became turbid when drugs were incorporated into the polymer matrix, lenses were only loaded within the lateral rim, therefore the core of the IOL remained unloaded, and thus clear. Polymer rods were soaked for limited time periods, hence soaking media could only diffuse into the outer rim. After the solvent evaporation, the polymer rods were sliced and IOLs were drilled out. During the release study, perfect optical properties were guaranteed in the center of the IOLs, whereas the outer rim of the IOLs became turbid, attributed to the drug precipitation. Although due to the smaller amount of polymer which was drug-loaded, the total loading decreased, the extended drug release was demonstrated. For potent drugs (e.g. dexamethasone) these lateral drug loadings were sufficient to achieve therapeutic effects. In conclusion, intraocular lenses were loaded with drugs and extended release patterns were achieved. For the different polymer compositions of intraocular lenses, diverse loading approaches were required. Hydrophilic and amphiphilic polymers could be successfully loaded by soaking, while hydrophobic acrylates required drug coatings on the lens surfaces, due to the low water content, followed by insufficient drug diffusion within the lenses. Furthermore, a specific two chamber device was suggested, to improve lens long-term stability and to avoid a premature drug release. Since drug-loaded lenses should be supplied in dry conditions to improve stability and to avoid a premature drug release, a specific two chamber device was suggested. The drug-loaded hydrophilic IOLs were stored in dry state and rehydration in a sterile environment was possible within 30 minutes. Foldability of amphiphilic and hydrophobic lenses was ensured also for unhydrated lenses. Dual loaded IOLs, presented the desired release patterns for both drugs simultaneously, thus the frequent drug administration after cataract could be avoided. Therefore, drug-eluting intraocular lenses are very promising devices for ocular drug delivery!
Degree
thesis:*- Department dc:contributor.department
- Biologie, Chemie, Pharmazie
- Year dc:date.issued
- 2018
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Heck, Marius
- Committee members dc:contributor.committeemember
-
- Bodmeier, Roland
- Maincent, Philippe
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier URI
- https://refubium.fu-berlin.de/handle/fub188/23171