Freie Universität Berlin
The influence of an intraocular lens design with enlarged 7.0 mm optic on the visual and optic results after a cataract surgery
Abstract
dc:description.abstractPurpose: To determine the impact of intraocular lens (IOL) design with an enlarged 7.0 mm optic on the incidence of dysphotopsiae, visual acuity and contrast sensitivity after cataract surgery. Methods: A prospective monocentric randomized patient-blinded comparative clinical study was planned. Following preoperative consent and measurements, patients underwent cataract surgery with the implantation of two IOL designs – with a 7.0 mm optic and plate haptics (group 1) or with a 6.0 mm optic and C-loop haptics (group 2). In months 1, 3 and 12, follow-up patients were examined and answered a questionnaire regarding satisfaction, spectacle dependence, and the frequency and extent of positive and negative dysphotopsiae. Additionally, contrast sensitivity in the second and third examination, and mesopic vision and glare sensitivity in the third examination were tested. The data were analysed as nominal, ordinal and metric values. Results: Group 1 comprised 57 eyes (43 patients) and group 2 comprised 63 eyes (43 patients). The corrected distance visual acuity was the same between groups and throughout the study. Uncorrected distance visual acuity was higher in group 1 in the first examination, with no differences in further follow-ups. Group 1 showed a lower incidence of positive and negative dysphotopsiae, with significant difference compared to group 2 in the first follow-up (p = 0.021 and 0.015, respectively). The frequency and partial extent of dysphotopsiae were lower throughout the whole study in group 1, reaching statistically significant values for the frequency of negative dysphotopsiae (p = 0.048) in the first examination. The mean contrast sensitivity and mesopic vision with and without glare were the same in both groups. Persistent positive dysphotopsiae cases revealed lower photopic contrast sensitivity (p = 0.005, 0.036 and 0.047), longer AL (p = 0.04) and greater preoperative pupil dynamics (p = 0.06), whereas cases with persistent negative dysphotopsiae were of significantly younger age (p = 0.029). Conclusions: The IOL design with a 7.0 mm optic diameter reduces positive and negative dysphotopsiae and provides good and stable visual acuity, contrast sensitivity, and mesopic vision with and without glare.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2022
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Bonsemeyer, Małgorzata
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-35535-9
- Identifier URI
- http://dx.doi.org/10.17169/refubium-35250