Freie Universität Berlin
RF Heating Effects and NMR-Based Thermometry with Hyperpolarized Xenon for Optimized CEST MRI
Abstract
dc:description.abstractWith the approval of hyperpolarized 129Xe as a clinical MRI agent for lung imaging, ad-ditional applications of 129Xe with saturation transfer NMR in other fields such as NMR thermometry and molecular imaging have gained interest. Pulsed-shaped saturation for HyperCEST molecular imaging has been introduced earlier but under unsuitable conditions, making it hard to identify a true benefit in shaped RF pulses and to com-pare associated heating effects. This motivates the investigation of 129Xe NMR but also requires thermometry calibration and quantification of RF heating effects. In one part of this thesis, temperature-induced shifts for signals of caged Xe are studied for the first time in more detail. In another one, the effects of RF heating in HyperCEST NMR are investigated in a systematic comparison of RF responses using two types of 129Xe hosts while exploring options for optimization of the saturation scheme. The heating effect sensed by 129Xe was analyzed in water and dPBS with different RF power, duty cycle, saturation time, and pulse shape. Two 129Xe hosts, cryptophane-A monoacid (CrA-ma) and cucurbit-6-uril (CB[6]), with moderate and fast exchange rates, were studied in z-spectra for 5 to 20 seconds of pulsed saturation. The pulse power was in the range of 13 µT to 58 µT. Analysis was done by fitting exponential Lorentzi-ans to the z-spectra. No heating difference was observed for applying 10 sec of saturation or 1 sec of satu-ration for 10 loops. As expected, the solvent type affects the heating, as it was observed 55% more heating in a saline solution compared to pure water under otherwise same conditions. Considering the average power equivalent, a 100 mW (31 µT) block pulse (BP) requires comparison with a 286 mW (51 µT) dSNOB and a 343 mW (57 µT) Gauss pulse. The power equivalent-adjusted pulses show identical heating for BP, dSNOB, and Gauss-shaped pulses. Xe exchanging with CB[6] clearly benefits from stronger saturation whereas the CrA-ma response does not improve. The signals of the two hosts have better temperature sensitivity compared to the PRF method as the CrA-ma signal shifts by 0.26ppm/°C and the CB[6] signal shifts by 0.09ppm/°C. Saturation with shaped pulses does not bring an apparent benefit compared to BP sat-uration when comparing for the same duration and effective B1. Previous studies only demonstrated that stronger or longer pulses will obviously have better performance. The overall width of the CEST responses is dominated by the exchange kinetics and is almost independent of the pulse shape for the conditions tested here. Only at high powers, the dSNOB pulse might be slightly more selective than the BP.
Degree
thesis:*- Department dc:contributor.department
- Charité - Universitätsmedizin Berlin
- Year dc:date.issued
- 2026
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hernandez Solarte, David Antonio
- Committee member dc:contributor.committeemember
-
- N.N.
Subjects
dc:subject × 3Rights
dc:rights.accessrights- Statement dc:rights.accessrights
-
- open access
- Licence dc:rights.uri
- Language dc:language
- eng
Identifiers
dc:identifier.*- URN
- urn:nbn:de:kobv:188-refubium-51646-6
- Identifier URI
- http://dx.doi.org/10.17169/refubium-51374