Back to search

Georgia Institute of Technology

Assessment of repetitive facilitation exercise with fMRI-compatible rehabilitation device for hemiparetic limbs

Abstract

dc:description.abstract

In order for stroke subjects to gain functional recovery of their hemiparetic limbs, facilitation techniques such as the repetitive facilitation exercise, or RFE, have been developed. Currently, there is a lack of understanding of the neural mechanisms associated with these types of facilitation techniques. To better understand the neural mechanisms associated with the RFE a functional magnetic resonance imaging (fMRI) study should be conducted. This thesis presents experimental results testing the feasibility of implementing an fMRI-compatible actuator to facilitate a myotatic reflex in synchronization with the subject’s intention to move their hemiparetic limb. Preliminary data from a healthy individual demonstrated the feasibility of overlapping the long latency component of the afferent myotatic reflex, created by electrical stimulation, with descending nerve impulses, created using transcranial magnetic stimulation, in a time window of 15ms. In addition, a pneumatic actuation time delay due to long transmission line was evaluated. The pneumatic actuator met the timing precision requirement for the rehabilitation device for varying transmission line lengths. Therefore a pneumatic actuation system was chosen for the rehabilitation device. This thesis will also presents on the design of an fMRI-compatible pneumatic actuator device to excite a stretch reflex response. Initial, experimental results with the device demonstrated that the designed pneumatic device can control the timing of the muscle response with a fixed signal within the required 15ms window required for cortical facilitation, which was found in the previous feasibility study. However, the device was unable to create a long latency reflex observable at the muscle. Finally, this thesis presents on the capability of the device in creating subthreshold long latency response with precision to overlap with a subthreshold descending nerve impulse, created using transcranial magnetic stimulation. The overlap of the two responses was evaluated by comparing the amplitude of the muscle response with and without the stretch reflex, created by the fMRI-compatible pneumatic actuator device. Varying time delays were analyzed.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lacey, Lauren Elizabeth
Advisor dc:contributor.advisor
  • Ueda, Jun
Committee members dc:contributor.committeemember
  • Book, Wayne
  • Shinohara, Minoru

Subjects

dc:subject × 11

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/51879

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Lacey, Lauren Elizabeth. Assessment of repetitive facilitation exercise with fMRI-compatible rehabilitation device for hemiparetic limbs. Masters thesis, Georgia Institute of Technology, 2014. http://hdl.handle.net/1853/51879