Back to search

Georgia Institute of Technology

Investigation of fluid dynamic effects of endovascular intervention in a model of descending aortic dissection

Abstract

dc:description.abstract

With advances in endovascular technology and technique, Thoracic EndoVascular Aortic Repair (TEVAR) has emerged as an integral component of the management of Stanford Type B dissection of the descending aorta. Whereas this modality is considered vital in the treatment of patients experiencing severe complications as a result of dissection, it has not been shown to be demonstratively superior to treatment with medical therapy alone in the absence of malperfusion, rupture, or aneurysmal degeneration. However, results from various clinical studies on the relative benefits of these therapies may be confounded by the vast heterogeneity in dissection anatomy and hemodynamics. Therefore, little is known regarding which patients should undergo TEVAR, as well as the effect of stent-graft deployment on the functional status of the aorta. In order to address this knowledge gap, compliant models of the aorta possessing a mobile intimal flap mimicking dissection were fabricated and imaged via four-dimensional phase contrast magnetic resonance (4D PCMR) imaging sensitive to fluid flow. We aimed to understand how the fluid flow varies with changes to the dissection anatomy as well as the effect of varying anatomies on the fluid shear rate, which has been related to the thrombotic potential of blood-contacting surfaces. Furthermore, we aimed to study the effects of graft deployment on these hemodynamic effects. Dissection induced flow reversal in the aorta, with concomitant low and oscillatory shear zones, which were reduced in dissections with multiple tears. Device deployment was found to restore normal hemodynamics locally, while preserving distal hemodynamic alterations. These findings suggest a potential for risk-stratification based on anatomical and functional imaging as well as more aggressive intervention to rectify aberrant fluid mechanics of the dissected aorta.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Biomedical Engineering (Joint GT/Emory Department)
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Birjiniuk, Joav
Advisors dc:contributor.advisor
  • Oshinski, John N.
  • Ku, David N.
Committee members dc:contributor.committeemember
  • Veeraswamy, Ravi K
  • Taylor, W. Robert
  • Sun, Wei
  • Dixon, J. B

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/58687

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Birjiniuk, Joav. Investigation of fluid dynamic effects of endovascular intervention in a model of descending aortic dissection. Doctoral thesis, Georgia Institute of Technology, 2017. http://hdl.handle.net/1853/58687