Back to search

Georgia Institute of Technology

Gait optimization with a real-time closed-loop artificial sensory feedback

Abstract

dc:description.abstract

Individuals with unilateral lower limb musculoskeletal and neurological conditions, including prosthetic users, experience asymmetric walking. It may result in undesirable compensations by the body and secondary conditions (osteoarthritis, low back pain, etc.). My goal was to develop a real-time closed-loop control system for a sensing, bone-anchored transtibial prosthesis interfaced with residual peripheral nerves and muscles. The prosthesis and control system would allow users to sense ground contact during walking and control the prosthetic ankle using natural motor commands to automatically correct asymmetries and instability of walking. To inform the design of the prosthesis and control system, I investigated in walking cats the effects of manipulating tactile sensory feedback from paw pads and stretch-dependent feedback from thigh muscles on symmetry and stability of walking. I found that removal of tactile and muscle length-dependent feedback resulted in profound changes in symmetry and stability of walking. In addition, electrical stimulation of the distal tibial nerve, innervating paw pads, during the stance phase of walking substantially reduced and sometimes reversed effects of sensory feedback removal. I then demonstrated that a real-time closed-loop gait control system could control step length symmetry of walking cats by stimulation of the distal tibial nerve. This system could be used for correcting asymmetries during walking in people with sensorimotor deficits. I also developed a prototype of a sensing transtibial prosthesis with an ankle joint controlled by activity of residual muscles. The results of this study provide new insights into the role of sensory feedback in control of locomotion and offer new engineering solutions for bone-anchored, limb neuro-prostheses and for improving pathological gait.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Electrical and Computer Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Park, Hangue
Advisors dc:contributor.advisor
  • Prilutsky, Boris I.
  • DeWeerth, Stephen P.
Committee members dc:contributor.committeemember
  • Butera, Robert J.
  • Chang, Young-Hui
  • Grover, Martha A.
  • Lemay, Michel A.

Subjects

dc:subject × 4

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/60148

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Park, Hangue. Gait optimization with a real-time closed-loop artificial sensory feedback. Doctoral thesis, Georgia Institute of Technology, 2017. http://hdl.handle.net/1853/60148