Back to search

Georgia Institute of Technology

CMUT array design and fabrication for high frequency ultrasound imaging

Abstract

dc:description.abstract

High frequency ultrasound imaging is utilized in a broad range of applications from intravascular imaging to small animal imaging for preclinical studies. Capacitive micromachined ultrasonic transducers (CMUTs) possess multiple preferable characteristics for high frequency imaging systems, such as simpler fabrication methods, simpler integration to electronics, and greater variety of array geometries. Adequate performance and optimization of CMUT based systems require a comprehensive analysis of multiple design parameters. This research utilizes a nonlinear lumped model, capable of simulating the pressure output, electrical input-output, and echo response to a planar reflector of CMUT arrays with arbitrary membrane shape and array geometry, to determine the performance limitations of high frequency CMUT arrays and the effect of different design parameters on its performance. Receiver performance is analyzed through parameters extracted from simulations, namely, thermal mechanical current noise, plane wave pressure sensitivity, and pressure noise spectrum. Transmitter performance is analyzed through pressure output simulation, and the overall performance is analyzed through the simulated pulse-echo response from a perfect planar reflector and the thermal mechanical current noise limited SNR. It is observed that the frequency response is dominated by two vibroacoustic limiting mechanisms: Bragg’s scattering, determined by array lateral dimensions, and crosstalk actuated fundamental and antisymmetric array modes, determined by individual membrane dynamics. Based on the limiting mechanism frequencies, a simplified design methodology is developed and used to design two CMUT array sets covering a broad frequency range of 1-80MHz. These CMUT arrays are fabricated and their limiting mechanisms are experimentally verified through pressure and admittance measurement and simulation comparison. CMUT arrays for guidewire IVUS application are implemented and successfully interfaced with ASICs to demonstrate imaging at 40MHz. Considering that CMUT array performance is also susceptible to the electrical termination conditions, the simulation model is utilized to investigate the effect of different impedance matching scenarios. Receiver performance of the integrated CMUT array and termination circuitry is analyzed through the system’s SNR and acoustic reflectivity.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Arkan, Evren Fatih
Advisor dc:contributor.advisor
  • Degertekin, F. Levent
Committee members dc:contributor.committeemember
  • Sabra, Karim
  • Hesketh, Peter
  • Arvanitis, Costas D.
  • Lindsey, Brooks

Subjects

dc:subject × 6

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1853/64601

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Arkan, Evren Fatih. CMUT array design and fabrication for high frequency ultrasound imaging. Doctoral thesis, Georgia Institute of Technology, 2020. http://hdl.handle.net/1853/64601