Back to search

Georgia Institute of Technology

Design and optimization of mini-beam GRID and LATTICE therapy using linear accelerators

Abstract

dc:description.abstract

Dose-Volume effects have been shown to increase the radiation dose tolerance of critical organs-at-risk (OARs) in multiple normal tissues such as the brainstem, spinal cord, parotid glands and in animal models. The irradiated volume must be kept “small” on the order of millimeters for tissues to experience additional protection from dose-volume effects. Mouse ears have demonstrated minimal toxicity from more than 60 Gy of single-fraction dose when the beam width was kept below 2 mm. Spatially Fractionated Radiation Therapy (SFRT) aims to deliver heterogeneous peak and valley dose regions to the tumor in contrast to homogeneous dose techniques such as intensity modulated radiotherapy (IMRT). A form of SFRT called minibeam radiation therapy (MBRT) typically uses beams on the order of sub-millimeter to a few millimeters which is within the size range for exploitation of dose-volume effects, but the connection between SFRT, MBRT and dose-volume effects has not been thoroughly explored. Glioma and glioblastoma are aggressive, radioresistant primary brain tumors with bleak prognosis and minimal treatment options, but LINAC-based photon MBRT in an animal study demonstrated complete tumor response for glioma when compared to stereotactic radiosurgery which only showed partial tumor remission. These results motivated this thesis work to develop novel techniques for delivering LINAC-based MBRT for overcoming radioresistance of aggressive tumors such as glioma/glioblastoma. In this thesis, the novel techniques of 2D “en face” honeycomb LINAC-MBRT, 3D “mini-LATTICE”, and “4π-MBRT” are developed and explained. This thesis will show that with modifications to existing commercially available medical linear accelerators, LINAC-MBRT can be implemented with MV-photon beams to increase the therapeutic ratio and treatment outcomes of radioresistant diseases such as glioma/glioblastoma.

Degree

thesis:*
Level thesis:degree_level
Doctoral
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Georgia Institute of Technology
Year dc:date.issued
2024

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Carter, Zachary Gray
Advisor dc:contributor.advisor
  • Wang, C.-K. Chris
Committee members dc:contributor.committeemember
  • Brooks, Kenneth
  • Elder, Eric
  • Roper, Justin
  • Erickson, Anna

Subjects

dc:subject × 14

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1853/75677

Chain of custody

source
Harvested from
Georgia Tech
Base URL
repository.gatech.edu/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation