Back to search

National and Kapodistrian University of Athens

Αξιολόγηση δύο αμιγώς ολοκεραμικών διαβλεννογονίων εμφυτευματικών τμημάτων εσωτερικής ένωσης: ITI Straumann – Xive, Friadent

Abstract

dc:description

PURPOSE: The aim of the study was to evaluate the characteristics of two commercially available all-ceramic dental implant abutments. MATERIALS AND METHODS: Two different types of all-ceramic dental implant abutments were used: (a) ITI Anatomic IPS e.max, ITI Dental Implant System, Institute Straumann AG, Waldenburg, Switzerland and (b) Dentsply, Friadent, Xive Cercon Abutment Straight. One specimen from each implant system was evaluated for the inter-proximal contacts between ceramic abutment and internal surfaces of the main implant body. This evaluation had been made by taking digital bitewings before and after the final torquing of the dental abutments. The examined digital bitewings were bigger than the classical ones and with higher resolution. The preload of two dental abutments, one of each system, have been measured five times for each specimen. Each measurement had been recorded with a digital torquing machine. Between torquing and untorquing there was an interval of two minutes. Ten dental abutments of each system had been tested for dynamic load on Instron machine at speed of 5 mm/minute and the final fracture loads had been recorded. The results had been compared between the tested implant systems and between implant systems which are using the same material but different construction method for their dental implant abutments.RESULTS AND CONCLUSIONS:The results of this study showed that:i) Prefabricated all-ceramic dental implant abutments with internal connection can withstand greater forces than those, which are applied on the natural teeth intraorally. ii) The average fracture load of each tested system was not significant different, but with differences at the peaks (minimum and maximum loads). iii) The average fracture load of each tested system was close to other ceramic systems made by the same material-Zirconium, but with different construction design. iv) The inter-proximal contacts of the implant abutment and the main implant body were different before and after the final torquing mainly for the Friadent, Dentsply sytem. v) The inter-proximal contacts of the implant abutment and the main implant body were different between the two tested systems. The ITI Straumann system had much better contacts. vi) The average fracture load was different between the two systems, but no statistically significant, maybe because of the difference shape and length between them. Stronger at the average fracture load was the ITI Sraumann system (628.1 Nmm). vii) The average preload was a) 29.96 Ncm for the ITI Straumann implant system and b) 24.54 Ncm for the Friadent, Dentsply implant system.viii) For each system the dentist has to follow specific guidelines in order to obtain the desired results. ix) There is a need for further research in order to have better mechanical results between the connection of the abutment and the main implant body.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Pallis, Konstantinos
  • Πάλλης, Κωνσταντίνος

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/28586

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Pallis, Konstantinos; Πάλλης, Κωνσταντίνος. Αξιολόγηση δύο αμιγώς ολοκεραμικών διαβλεννογονίων εμφυτευματικών τμημάτων εσωτερικής ένωσης: ITI Straumann – Xive, Friadent. National and Kapodistrian University of Athens, 2012. http://hdl.handle.net/10442/hedi/28586