dc:descriptionWidespread damage to steel moment frame structures during the 1994 Northridge and 1995 Cobe earthquakes led researchers to develop alternative connection designs to the prescriptive pre-Northridge moment connection. Two key concepts have been developed to provide highly ductile response and reliable performance; strengthening the connection and/or weakening the beam framing to the column, in order to avoid damages of the respective column. The weakening of specific sections of the beam in order to change them into reliable energy dissipative zones, in case of an earthquake, is an idea which was developed in principle in the late ‘80s by Andre Plumier. There has been previous testing on the RBS moment connections which heralds the effectiveness of the new approach in the post-Northridge design era. The reduced beam section (RBS), allows controlled yielding of the beam by moving the plastic hinge region at the beam-in a short distance from the column’s face-protecting the connection from any type of failure. Various shapes cutouts are possible (constant, tapered or radius cut) to reduce the cross sectional area. Extensive experimental and analytical projects have been conducted demonstrating that the curved RBS behaves with the highest rotational capacity. Recommendations for the design and detailing of the RBS member were prescribed in FEMA 350 and FEMA 351, regarding the location and reduction rate of RBS, based on the local performance of tested beam to column assemblies. In Europe, also, following the concept of the above mentioned recommendations, in EC8, Part 3, design of such type of connections is presented. It can be noted that the “a” and “b” values from EC8, Part 3 are the average values as compared with FEMA 350, while for “g” (or “c”), “s” and “r” the same values were adopted. The effectiveness of these recommendations is questionable for welded beam to column connections. A recent experimental research confirmed the need for readjustment of the geometrical characteristics for the design of the RBS, with radius cut. In this dissertation the behaviour of the RBS moment connection with extended endplate - widely used in beam to column moment connections in Europe - subjected to cyclic loading and using the European profiles is examined. Experimental and Finite Element Analysis approaches were conducted investigating the adopted by EC8, Part 3 key parameters for the design. Comparing the extracted results from both approaches, the need for further investigation - concerning the effectiveness of the RBS use in this type of connections and for the possible readjustment of the geometrical characteristics of the RBS - is imperative in order to be safely applied to the European profiles.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2013
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Sofias, Christos
- Σοφίας, Χρήστος
Subjects
dc:subject × 20- Κοχλιωτή σύνδεση ροπής δοκού-υποστυλώματος
- Εκτεταμένη μετωπική λεπίδα
- Απομείωση
- Εναλλασσόμενη φόρτιση
- Ανάλυση με πεπερασμένα στοιχεία
- Πειραματικός έλεγχος
- Στροφική ακαμψία
- Bolted beam to column connection
- Extended endplate
- Dogbone
- Cyclic loading
- Finite element analysis
- Experimental study
- Rotational stiffness
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Επιστήμη Μηχανολόγου Μηχανικού
- Engineering and Technology
- Civil Engineering
- Mechanical Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/30048