Back to search

National and Kapodistrian University of Athens

Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής

Abstract

dc:description

Introduction: Mechanical aortic properties have been shown to transiently deteriorate in the early post-operative after surgical interventions in the aortic valve (or root) replacement. Aortic stiffness is an independent predictor of cardiovascular risk and mortality. Aim: To evaluate the effect of Transcatheter Aortic Valve Implantation (TAVI) on ascending aorta's elasticity. Methods: Aortic stiffness indices were measured non-invasively (echocardiographically) at baseline, 7 days and 1 month post TAVI and invasively (angiographically) acutely pre- and post- TAVI. Invasive evaluation was conducted for two levels of the ascending aorta (3 cm and 6 cm above aortic valve). Results: A total of 30 patients (47% males) were studied with a mean age of 79.9 ± 4.7 years. No significant changes in aortic stiffness indices (aortic distensibility, aortic compliance, aortic stiffness index) were observed. In particular, aortic distensibility remained unchanged post-TAVI as evaluated both non-invasively (from 1.89 ± 1.11 at baseline, to 2.05 ± 1.50 at 7 days post-TAVI, to 1.84 ± 1.34 cm2/(dynes*106); p=0.497) and invasively (at the 3 cm above aortic valve level: from 0.88 ± 0.44 pre- to 0.82 ± 0.47 cm2/(dynes*106) post- TAVI, p=0.637. Results were similar at the 6 cm above aortic valve level. Conclusion: TAVI has no effect on mechanical properties of the ascending aorta in the early post-operative period (up to 1 month).

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2014

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Vrachatis, Dimitrios
  • Βραχάτης, Δημήτριος

Subjects

dc:subject × 16

Rights

dc:rights
Statement dc:rights
  • BY_NC
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/37154

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Vrachatis, Dimitrios; Βραχάτης, Δημήτριος. Διακαθετηριακή εμφύτευση τεχνητής αυτοεκπτυσσόμενης βιοπροσθετικής αορτικής βαλβίδας για την αντιμετώπιση συμπτωματικής σοβαρής αορτικής στένωσης: επίδραση στις μηχανικές ιδιότητες της αορτής. National and Kapodistrian University of Athens, 2014. http://hdl.handle.net/10442/hedi/37154