Aristotle University Of Thessaloniki (AUTH)
Εκτίμηση της σταθερότητας της κεντρικής ασφάλισης του ενδομυελικού ήλου στα κατάγματα του άνω τριτημορίου της κνήμης
Abstract
dc:descriptionIntramedullary nailing is the gold standard treatment of diaphyseal fractures of the tibia. As a result of this gain in popularity, the indications for intramedullary nailing have expanded to more proximal fracture patterns. However, when the same method is used for extra-articular fractures of the proximal tibia, various problems can occur. This has led to the improvement of the design of the intramedullary nails in order to accommodate multiple locking screws in various directions. The objective of the present biomechanical study is to compare the stability of six tibial nails when they are used for the treatment of unstable, extra-articular, proximal tibial fractures. Thirty composite tibia models were divided in six groups and a different nail was implanted in each group. The maximum number of proximal screws was used for each specimen and a proximal 2 cm gap osteotomy was performed. All specimens underwent biomechanical loading in two modes. The first mode was fatigue testing with low, eccentric loads for 100000 cycles and the second mode was axial static loading with higher loads. During the first mode, data acquisition was performed every 10.000 cycles and the stiffness of the construct was calculated. For each specimen, a comparison of the stiffness of every step up to 100.000 cycles was performed, in order to identify any irregular behavior or mechanical failure. Each specimen’s mechanical properties remained stable up to 100.000 cycles without any failure or irregularity. Average stiffness for each group was compared pair wise in a post-hoc fashion. Results of the post-hoc procedure suggest that groups D and E differ from all others, with D having the highest values and E the lowest. Stiffness values of a solid nail with two proximal screws and a cannulated nail with five screws were significantly higher compared to all other groups. On the other hand, a titanium cannulated nail with three screws showed the lowest rigidity. Solid nails provide more rigidity compared to cannulated ones and the maximum number of proximal screws in all possible directions should be used in order to achieve maximum stability. During the second mode average stiffness for each group was recorded in a longitudinal setting. Generalized Estimating Equations (GEE) modeling was used for inference as a result. Group D differs from all other models in this setting, having the highest values, while group E differs from F only. We came to the conclusion that on this mechanical model a person weighing up to 100 kilograms can fully weight bear with a nail from group D without creating excessive motion at the fracture site more than one millimeter. On the other hand, nails from group E showed that with a person weighing more than 56.1 kilograms they allow excessive micro-motion when the person fully weight bears. As a result when it comes to postoperative instructions, it is mandatory to take into account the patient’s body weight and advise patients to partially weigh bear with a load generally less than 50 kilograms, until there are signs of fracture healing.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Gkouvas, Georgios
- Γκούβας, Γεώργιος
Subjects
dc:subject × 12Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/46980