Validity and Reliability of the Balance Tracking System™ During Static Stance
Abstract
dc:description.abstractIntroduction: The Balance Tracking System™ (BTrackS™) is a balance board designed to quickly analyze postural control through center of pressure (COP) analysis. Purpose: Examine concurrent validity and test-retest reliability of the BTrackS™ during static stance. Methods: A convenience sample of 51 healthy collegiate students between 18 - 25 years old (21.8 ± 3.1 years) completed four, 20 second (s) trials of feet together static stance during both eyes open and closed trials. Data was simultaneously collected on the BTrackS™ and a laboratory force plate to establish concurrent validity. A second testing session was administered 48 - 72 hours later to establish test-retest reliability. Independent variables were device (BTrackS™/force plate) and time (Time Point 1/Time Point 2). Dependent variables were anterior-posterior (AP) and medial-lateral (ML) COP excursion. Eight Pearson’s Product Correlations were used to compare the relationship of dependent variables between the BTrackS™ and laboratory force plate. Four Intra-Class Correlations (ICC) were used to compare the relationship of dependent variables between Time Point 1 and Time Point 2 measured by the BTrackS™. Four 2 x 2 (device x time) repeated measures ANOVA’s were used to determine the magnitude of differences within independent variables. Results: Pearson Product Correlations showed an excellent relationship (r = 0.867 – 0.968) between the BTrackS™ and laboratory force plate. However, the 2 x 2 repeated measures ANOVA’s showed a significant difference between devices during both eyes open and closed conditions for all dependent variables (p < 0.001). Intra-Class Correlations showed an excellent relationship (ICC = 0.859 – 0.984) between time points for the BTrackS™. The 2 x 2 repeated measures ANOVA’s showed no significant differences between time points for the BTrackS™ during eyes open and closed conditions for all dependent variables (p = 0.185 – 0.976). Conclusion: Findings suggest that the BTrackS™ is strongly correlated with a laboratory force plate, but is significantly different. The BTrackS™ is strongly correlated and not significantly different within 48 - 72 hours. Additional research regarding an acceptable difference between the BTrackS™ and a laboratory force plate is warranted before it can be used clinically.
Degree
thesis:*- Name thesis:degree_name
- Master of Science in Kinesiology (M.S.)
- Level thesis:degree_level
- Thesis (open access)
- Discipline thesis:degree_discipline
- Department of Health and Kinesiology
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Grotewold, Cody L
- Contributors dc:contributor
-
- Nicholas Murray
- Tamerah Hunt
Subjects
dc:subject × 6Rights
- Licence dc:rights.license
Identifiers
dc:identifier.*- Repository record dc:identifier
- https://digitalcommons.georgiasouthern.edu/etd/1564