Validity and Reliability of the Balance Tracking System™ During Static Stance

Abstract

dc:description.abstract

Introduction: The Balance Tracking System™ (BTrackS™) is a balance board designed to quickly analyze postural control through center of pressure (COP) analysis. Purpose: Examine concurrent validity and test-retest reliability of the BTrackS™ during static stance. Methods: A convenience sample of 51 healthy collegiate students between 18 - 25 years old (21.8 ± 3.1 years) completed four, 20 second (s) trials of feet together static stance during both eyes open and closed trials. Data was simultaneously collected on the BTrackS™ and a laboratory force plate to establish concurrent validity. A second testing session was administered 48 - 72 hours later to establish test-retest reliability. Independent variables were device (BTrackS™/force plate) and time (Time Point 1/Time Point 2). Dependent variables were anterior-posterior (AP) and medial-lateral (ML) COP excursion. Eight Pearson’s Product Correlations were used to compare the relationship of dependent variables between the BTrackS™ and laboratory force plate. Four Intra-Class Correlations (ICC) were used to compare the relationship of dependent variables between Time Point 1 and Time Point 2 measured by the BTrackS™. Four 2 x 2 (device x time) repeated measures ANOVA’s were used to determine the magnitude of differences within independent variables. Results: Pearson Product Correlations showed an excellent relationship (r = 0.867 – 0.968) between the BTrackS™ and laboratory force plate. However, the 2 x 2 repeated measures ANOVA’s showed a significant difference between devices during both eyes open and closed conditions for all dependent variables (p < 0.001). Intra-Class Correlations showed an excellent relationship (ICC = 0.859 – 0.984) between time points for the BTrackS™. The 2 x 2 repeated measures ANOVA’s showed no significant differences between time points for the BTrackS™ during eyes open and closed conditions for all dependent variables (p = 0.185 – 0.976). Conclusion: Findings suggest that the BTrackS™ is strongly correlated with a laboratory force plate, but is significantly different. The BTrackS™ is strongly correlated and not significantly different within 48 - 72 hours. Additional research regarding an acceptable difference between the BTrackS™ and a laboratory force plate is warranted before it can be used clinically.

Degree

thesis:*
Name thesis:degree_name
Master of Science in Kinesiology (M.S.)
Level thesis:degree_level
Thesis (open access)
Discipline thesis:degree_discipline
Department of Health and Kinesiology

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Grotewold, Cody L
Contributors dc:contributor
  • Nicholas Murray
  • Tamerah Hunt

Subjects

dc:subject × 6

Rights

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.georgiasouthern.edu/etd/1564

Chain of custody

source
Harvested from
Georgia Southern University
Base URL
digitalcommons.georgiasouthern.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Grotewold, Cody L. Validity and Reliability of the Balance Tracking System™ During Static Stance. Thesis (open access) thesis, https://digitalcommons.georgiasouthern.edu/etd/1564