University of Guelph
Using Active Distributed Temperature Sensing to Evaluate Monitoring Interval and Seal Placement and Integrity of Backfilled Multilevel Systems
Abstract
dc:description.abstractThe use of backfilled multilevel systems in fractured bedrock aquifers has proven useful for monitoring hydraulic head and groundwater quality at multiple depths within a single borehole. Placement of backfill material at the intended depths is important for achieving the desired monitoring interval position, yet perfect placement and seal integrity of these intervals can be challenging. It is important therefore to assess the final placement and condition of bentonite seals to provide accurate monitoring data. A new approach using fibre optic Active Distributed Temperature Sensing (A-DTS) with a composite fibre optic cable deployed in the annular space is presented as an effective tool for quantifying the position of monitoring intervals and identifying issues associated with backfilling. A-DTS data, analyzed in three bedrock boreholes with backfilled multilevel systems in the Guelph, ON area, demonstrates clear boundaries between backfill materials allowing assessment of their positioning and the continuity of the bentonite seals.
Degree
thesis:*- Name thesis:degree_name
- Master of Applied Science
- Department thesis:degree_department
- School of Engineering
- Grantor dc:publisher
- University of Guelph
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Brown, Mitchell
- Advisor dc:contributor.advisor
-
- Parker, Beth
Subjects
dc:subject × 4Rights
dc:rights- Statement dc:rights
-
- Attribution-NonCommercial 4.0 International
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- https://hdl.handle.net/10214/27879