Back to search

University of Guelph

Air Lift Pump Performance Operating Under Three-phase Flow Conditions

Abstract

dc:description.abstract

Solid particles introduction to airlift pumping system for mining applications has a remarkable impact on the multiphase flow behavior where additional forces due to solid presence will control pumping performance and efficiency. Further to these forces and in some cases depending on solid particles physical properties, concentration, and solubility, mixture physical rheology will be altered and the fluid dynamics will no longer behave as a Newtonian fluid. Despite of numerous experiments conducted to correlate measured results with constructed performance models, inconsistencies were noted when utilizing these models over a wide range of system applications due to variations in the experimental setups, different environmental conditions, and the exclusion of other critical controlling factors. This study explores the relevant trends and physics that can affect airlift systems performance under three-phase flow. An experimental setup simulating system application was designed, constructed, and tested under different Geometrical and Operational conditions, where three submergence ratios, solids of different physical properties, and two injector head designs at different air volumetric rates were evaluated. A system performance model was developed and evaluated using the current experimental results and correlated with experiments conducted by previous researchers. Solid particles deliverability increased at reduced particles size, and density and in particular at steady-state conditions. Higher submergence magnified the effect of particles physical properties on pumping system performance and results in early solid production accelerating the test cycle towards steady-state conditions, thus reducing the transition zone period which can cause pumping system failure. Performance enhancement was evident utilizing Swirl injector head over the Annular type only at lower submergence ratio under steady-state conditions.

Degree

thesis:*
Name thesis:degree_name
Master of Applied Science
Department thesis:degree_department
School of Engineering
Grantor dc:publisher
University of Guelph

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Taha, Marwan
Advisors dc:contributor.advisor
  • Ahmed, Wael
  • Moussa, Soha Eid

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Attribution 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10214/28181

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Taha, Marwan. Air Lift Pump Performance Operating Under Three-phase Flow Conditions. University of Guelph, https://hdl.handle.net/10214/28181