Back to search

University of Guelph

Studies of Light Element X-Ray Fundamental Parameters Used in PIXE Analysis

Abstract

dc:description.abstract

New measurements of fundamental parameters (FP), used in reference-free particle induced X-ray emission (PIXE) analysis of materials, may be assisted by incorporating both state-of-the-art spectral processing methods and methodologies that have minimal reliance upon other FPs. Under this heading, several light element FPs have been investigated. A collection of monochromatic spectra[73] have been characterized in terms of the origins and lineshapes of features arising due solely to photon and electron interactions in the silicon detector crystal. Through the assistance of Monte Carlo simulation results, state-of-the-art fit treatments were applied to these spectra using a fit routine that combined both non-linear least squares and manual optimization. The fitted spectra were used to derive a new estimate of the K X-ray fluorescence yield (ωK) of Si. This was done using a geometrical expression that relates ωK to the area ratio of the escape to primary peaks taken from the spectra. The final result (0.0504 ± 0.0015) was realized through assistance from new low energy mass-attenuation coefficient (MAC) data. The accuracy of low-energy (1–2 keV) MACs of light elements was assessed using an approach incorporating PIXE measurements on pure element (Mg, Al and Si) and oxide (MgO, Al2O3 and SiO2) targets. Calculated spectrometer efficiency constants, compared between target pairs (eg, Si vs. SiO2), allow many FPs to cancel. Any non-zero difference in the comparison indicates errors associated with the remaining FPs. A resultant 4–6% discrepancy was attributed to the use of XCOM[10] MACs but this was reduced to 0.5–2.5% using FFAST[33] MACs. Additional measurements, performed on silicate micro-probe standards, were analyzed using the same comparative approach. A light element efficiency-constant discrepancy of 7–9% was observed and attributed to the use of XCOM MACs. This was reduced to 0.5–3.5% using FFAST MACs but was reduced further to −0.5–2% using a combination of XCOM and FFAST MACs. This result suggested that the combination database was superior.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Department thesis:degree_department
Department of Physics
Grantor dc:publisher
University of Guelph
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Heirwegh, Christopher Michael
Advisor dc:contributor.advisor
  • Campbell, John L. (Iain)

Subjects

dc:subject × 11

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10214/8115

Chain of custody

source
Harvested from
University of Guelph
Base URL
atrium.lib.uoguelph.ca/server/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
related terms
citation

Heirwegh, Christopher Michael. Studies of Light Element X-Ray Fundamental Parameters Used in PIXE Analysis. University of Guelph, 2014. http://hdl.handle.net/10214/8115