Back to search

Kansas State University

Coordinated operations of distributed wind generation in a distribution system using PMUs

Abstract

dc:description.abstract

Wind energy is becoming one of the most widely implemented forms of renewable energy worldwide. Traditionally, wind has been considered a non-dispatchable source of energy due to the uncertainty of wind speed and hence the variable availability of wind power. Advances in technology allow the consideration of the impact of distributed wind turbines and farms on distribution systems. It is possible to combine the clean energy attributes of wind with the quickly dispatchable nature of a storage facility in order to provide the maximum amount of locally available power economically to the loads present on the distribution feeder. However, a monitoring and control system needs to be provided that is capable of detecting the changes associated with the distribution feeder load and also the variable generation output from the wind farms. This task can be accomplished using a Phasor Measurement Unit (PMU) which has very high sampling rates and hence can measure very rapid and dynamic changes in power levels associated with distribution feeder load and wind generation. The data which is obtained from these PMUs can be used to calculate the amount of distributed generation and storage that can be dispatched locally at the distribution feeder, thus resulting in a reduction in the peak load levels associated with the distribution feeder as seen by the substation monitoring system. Simulations will work to balance load requirements, wind generation output, and distributed storage providing a stable system utilizing maximum renewable resources. The standard IEEE 37-node distribution test feeder is used in the study. Probabilistic models are implemented for distribution feeder load, and the models are analyzed through simulations. Four different combinations of charging and discharging methods have been investigated. Two analytically different algorithms have been used for wind and battery dispatch, one based on forecasted load information and the other based on historical measurements obtained from PMUs. The strategies being investigated can also be used to implement other important applications such as distribution system state estimation, protection and instability prediction.

Degree

thesis:*
Level thesis:degree_level
Masters
Department dc:contributor.department
Department of Electrical and Computer Engineering
Grantor dc:publisher
Kansas State University
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Vijayarengan, Manoaj Srikumar
Advisor dc:description.advisor
  • Noel N. Schulz

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • © the author. This Item is protected by copyright and/or related rights. You are free to use this Item in any way that is permitted by the copyright and related rights legislation that applies to your use. For other uses you need to obtain permission from the rights-holder(s).
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/2097/15039

Chain of custody

source
Harvested from
Kansas State University
Base URL
krex.k-state.edu/server/oai/request
Last updated
2026-11-26
Source record
OAI-PMH GetRecord
citation

Vijayarengan, Manoaj Srikumar. Coordinated operations of distributed wind generation in a distribution system using PMUs. Masters thesis, Kansas State University, 2012. https://hdl.handle.net/2097/15039