Back to search

University of Manitoba

Corrosion and Fretting Corrosion Studies of medical grade CoCrMo implant material in a more clinically relevant simulated body environment.

Abstract

dc:description.abstract

In modular hip implants, micro-motion, which leads to fretting corrosion at the head/neck and neck/stem interfaces, has been identified as a major cause of early revision in hip implants, particularly those with heads larger than 32mm. It has been found that the type of fluid used to simulate the fretting corrosion of biomedical materials is crucial for the reliability of laboratory tests. Therefore, to properly understand and effectively design against fretting corrosion damage in modular hips, there is the need to replicate the human body environment as closely as possible during in-vitro testing and validation. In this work, corrosion behavior of CoCrMo in 0.14 M NaCl, phosphate buffered saline (PBS) and clinically relevant simulated body fluid (sbf) is carried out. Also, fretting corrosion studies of the CoCrMo alloy in a clinically relevant novel simulated body fluid (sbf) environment is studied. The presence of phosphate ions in PBS accounted for the higher corrosion rate when compared with 0.14 M NaCl and sbf environment. Despite the low and comparable corrosion rates in 0.14 M NaCl and sbf, the nature of the protective passive film formed in sbf shows the suitability of the novel sbf for future corrosion and fretting corrosion analysis. Finally, the influence of micro-motion at the modular head/neck and neck/stem interfaces on the concentration of metallic ions that goes into the synovial fluid and surrounding tissues is reported.

Degree

thesis:*
Level thesis:degree_level
Master of Science (M.Sc.)
Discipline thesis:degree_discipline
Mechanical and Manufacturing Engineering
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ocran, Emmanuel Kofi
Advisor dc:contributor.supervisor
  • Ojo, Olanrewaju (Mechanical and Manufacturing Engineering) Wyss, Urs (Mechanical and Manufacturing Engineering)
Committee members dc:contributor.committeemember
  • Morrison, Jason (Biosystems Engineering)
  • Brandt, Jan-M (Mechanical and Manufacturing Engineering)

Subjects

dc:subject × 5

Rights

Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1993/23602

Chain of custody

source
Harvested from
University of Manitoba
Base URL
mspace.lib.umanitoba.ca/oai/request
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Ocran, Emmanuel Kofi. Corrosion and Fretting Corrosion Studies of medical grade CoCrMo implant material in a more clinically relevant simulated body environment.. Master of Science (M.Sc.) thesis, 2014. http://hdl.handle.net/1993/23602