University of Maryland
The Evaluation of a Performance-Based Design Process for a Hotel Building: The Comparison of Two Egress Models
Abstract
dc:description.abstractThis work emphasizes the importance for egress model users to choose a model for each project with the appropriate input features and simulation capabilities. This report also gives model users a mechanism for choosing the appropriate model by providing a detailed egress model review (Chapter 2). Specifically this report focuses on the ability of two egress models, EXIT89 and Simulex, to simulate a high-rise hotel building evacuation. When EXIT89 and Simulex are used to 1) simulate the same design scenarios and 2) perform a bounding analysis of the hotel building, significant differences in egress times were identified. EXIT89's evacuation times were found to be 25-40% lower than Simulex for the design scenarios, attributed to differences in unimpeded speeds, movement algorithms, methods of simulating slow occupants, density in the stairs, and stair configuration input between the models. For the bounding analysis, EXIT89 produced maximum evacuation times 30-40% lower than Simulex.
Degree
thesis:*- Department dc:contributor.department
- Fire Protection Engineering
- Year dc:date.issued
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Kuligowski, Erica Dawn
- Advisors dc:contributor.advisor
-
- Milke, James A
- Bryan, John L
- Notarianni, Kathy A
Rights
- Language dc:language.iso
- en_US
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1903/114