Back to search

McMaster University

The Optimal Placement of Shutoff Rods in CANDU Nuclear Reactors (Part A)

Abstract

dc:description.abstract

<p> The optimal placement of shutdown systems in power reactors is investigated, in particular, the placement of mechanical and liquid shutoff rods. Two CANDU reactor cores were used as a basis for evaluation. The optimal shutdown system was defined here to be one which, with the least number of rods, maximizes the reactivity depth of the system with the two most effective rods assumed to be absent. It was found that rows of rods placed parallel to the fuel channels were more effective and four of these rows were required in a simple core. For real cores where positions are limited six or seven rows were needed to obtain a large system worth. (Time analysis was not done to evaluate insertion rate and delay effects on the power transient in the case of an accident.) </p>

Degree

thesis:*
Department dc:contributor.department
Engineering Physics
Year dc:date.issued
1975

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gordon, Charles W.
Advisor dc:contributor.advisor
  • Roshd, M. H. M.

Subjects

dc:subject × 1

Rights

Language dc:language.iso
en_US

Identifiers

dc:identifier.*

Chain of custody

source
Harvested from
McMaster University
Base URL
macsphere.mcmaster.ca/server/oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Gordon, Charles W.. The Optimal Placement of Shutoff Rods in CANDU Nuclear Reactors (Part A). 1975. http://hdl.handle.net/11375/18017