McMaster University
A Mechanistic Model to Predict Fuel Channel Failure in the Event of Pressure Tube Overheating
Abstract
dc:description.abstractUnder normal operating conditions a CANDU reactor pressure tube (PT) is insulated from its outer calandria tube (CT) by a CO2 gas annulus. If the primary loop coolant flow is compromised the PT can overheat and, if still pressurized, balloon into contact with the CT. At this point the moderator acts as an emergency heat sink. If the heat transferred from the CT to the moderator exceeds the critical heat flux (CHF) the CT can overheat, begin to strain due to the contact pressure, and eventually fail. A mechanistic model is presented that describes ballooning contact of the PT and CT, the resulting thermal contact conductance, heat flux to the moderator, and, if CHF is exceeded, the development of film boiling and potential CT strain. The goal is to create a software package that predicts fuel channel failure during a pressure tube overheat event.
Degree
thesis:*- Department dc:contributor.department
- Engineering Physics
- Year dc:date.issued
- 2016
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Dion, Alexander
- Advisor dc:contributor.advisor
-
- Luxat, John
Subjects
dc:subject × 4Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Identifier URI
- https://doi.org/10.71548/13719