Back to search

NJIT

An experimental study of equilibrium parametric pumps

Abstract

dc:description.abstract

<p>Parametric pumping is a separation process characterized by periodic changes in axial displacement, coupled with synchronized changes in some variable affecting the position of the interphase equilibrium. Both continuous and semicontinuous pumps were investigated at various operating conditions using a model system of toluene-n-hep-tane on a silica gel adsorbent. It has been shown that when the penetration distance for the cold cycle is less than or equal to that for the hot cycle and the height of the column, the pump has the capacity of complete removal of solute from one product stream. A quantity which is important in determining pump performance is the equilibrium parameter, b. Pump performance is enhanced by large interphase movement and hence by large values of the equilibrium parameter.</p>

Degree

thesis:*
Name thesis:degree_name
Master of Science in Chemical Engineering - (M.S.)
Discipline thesis:degree_discipline
Chemical Engineering and Chemistry

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Park, John A.
Contributors dc:contributor
  • Hung T. Chen
  • Jerome J. Salamone
  • Angelo J. Perna

Subjects

dc:subject × 2

Identifiers

dc:identifier.*
Repository record dc:identifier
https://digitalcommons.njit.edu/theses/2155

Chain of custody

source
Harvested from
NJIT
Base URL
digitalcommons.njit.edu/do/oai/
Last updated
2026-11-19
Source record
OAI-PMH GetRecord
citation

Park, John A.. An experimental study of equilibrium parametric pumps. https://digitalcommons.njit.edu/theses/2155