Monterey, California: U.S. Naval Postgraduate School
Design of an automatic flux level control system for the AGN-201 reactor
Abstract
dc:description.abstractThe simulation of the kinetic equations for the AGN-201 reactor was programmed on the Donner Model 3100 analog computer. The accuracy of the simulation was verified by comparison with both a digital computer solution of the kinetic equations and with the measured time response of the AGN-201 reactor. A discontinuous (on-off) type automatic flux control system was designed and placed in closed loop operation with the simulated reactor. The sensitivity of the control system was adjusted to obtain the specified performance. The control system was then installed on the AGN-201 and the accuracy of this design technique was verified by time response measurements. The control system proved to be a simple, effective device capable of maintaining the power (flux) level of the reactor within ± 3% of the desired level at all levels of reactor operation between 0.01 and 200 watts.
Degree
thesis:*- Name thesis:degree_name
- M.S. in Nuclear Engineering
- Level thesis:degree_level
- Masters
- Discipline thesis:degree_discipline
- Nuclear Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Monterey, California: U.S. Naval Postgraduate School
- Year dc:date.issued
- 1963
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Gans, George M., Jr.
- Advisor dc:contributor.advisor
-
- Gerba, Alex Jr.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- This publication is a work of the U.S. Government as defined in Title 17, United States Code, Section 101. Copyright protection is not available for this work in the United States.
- Approved for public release; distribution is unlimited.